12
Installation
4.3 HYDRAULIC INSTALLATION
4.3.1 Installation examples
7
12
h
1
2
5
6
3
4
h
8 9
10 11
1
2
5
6
7
12
1. To avoid undissolved particles, never suck the product to be injected from the bottom of the tank.
2. Filter. It is essential to install a filter (150 micron) in the suction piping.
3. Level sensor
4. Agitator
5. Make sure to collect any liquid leakage from the cylinder’s vent/drain orifice in a proper container.
6. Priming and drain valve built into the pump.
7. Pressure relief valve. Install a pressure relief valve in a bypass as close as possible to the pump
in order to protect the pump and the installation from possible overpressure. This bypass should pipe
the liquid to a safe place.
8. Pulse dampener
9. Pressure gauge.
10. Pressure maintenance valve.
11. Flowmeter
12. Injection check valve
Create Flow
info@createflow.cz
www.createflow.cz
Distribuce Create Flow
tel: +420 722 712 652