background image

 Be sure to read the instructions in this section carefully before use.
 Make sure  to observe  the instructions in this manual as the conventions of safety symbols and messages
 regarded as very important precautions are included.
 We also recommend you keep this instruction manual handy for future reference.

Safety Symbol and Message Conventions

Safety  symbols and messages  described  below are used in this manual  to prevent  bodily injury and  property 
damage  which  could  result  from  mishandling.  Before  operating  your  product,  read  this  manual  first  and
 understand the safety symbols and messages so you are thoroughly aware of the potential safety 

Indicates a potentially hazardous situation which, if mishandled, could
result in death or serious personal injury.

Indicates a potentially hazardous situation which, if mishandled, could
result in moderate or minor personal injury, and/or property damage.

When Installing the Unit

   Do not  expose  the unit   to rain or an  environment
   where it may be splashed by  water or other liquids, 
   as doing so may result in fire or electric shock.

   Use the unit only with the voltage   specified  on the
   unit.  Using  a  voltage  higher  than  that  which  is
   specified may result in fire or  electric shock.

   Do not cut, kink, otherwise damage   nor modify the
   power  supply  cord.  In  addition,  avoid  using  the
   power cord in close proximity to heaters,  and never
   place heavy objects -- including the unit   itself -- on 
   the  power  cord,  as  doing so may result  in  fire or  
   electric shock.

 Be sure  to replace  the unit's   terminal  cover  after
 connection  completion.  Because  high  voltage   is
 applied to the speaker terminals, never touch these  
 terminals to avoid electric shock.

 Be  sure  to  ground  to  the  safety   ground  (earth)
 terminal to avoid electric shock. Never   ground to a 
 gas pipe as a catastrophic disaster may result.

 Avoid  installing  or  mounting  the  unit  in  unstable
 locations, such  as   on a rickety  table   or  a slanted
 surface.  Doing  so  may  result  in  the  unit   falling
 down,   causing   personal   injury  and/or  property 
 damage.

When the Unit is in Use

   Should  the  following  irregularity  be  found  during 
   use, immediately switch  off  the  power, disconnect
   the  power  supply   plug  from  the  AC  outlet  and 
   contact  your  nearest  

  dealer. Make no further

   attempt  to operate the unit in this   condition as  this
   may cause fire or electric  shock.
     If  you  detect  smoke  or  a strange  smell coming
     from the unit.
     If water or any metallic object gets into the unit
     If the unit falls, or the unit case breaks
     If the power supply cord is damaged (exposure  of
     the core, disconnection, etc.)
     If it is malfunctioning (no tone sounds.)

   To prevent  a fire or electric  shock, never open  nor
   remove  the  unit  case  as  there  are  high  voltage 
   components  inside  the  unit.  Refer all servicing to
   your nearest  

 dealer.

ITC

ITC 

 Do  not  place  cups,  bowls,   or other containers  of
 liquid  or  metallic  objects on top  of the unit. If  they 
 accidentally spill  into the unit, this may cause  a fire 
 or electric shock.

  Do   not   insert    nor   drop    metallic    objects   or 
  flammable  materials  in  the   ventilation slots  of the
  unit's  cover,  as  this  may  result   in  fire  or electric
   shock.

1. SAFETY PRECAUTIONS

3

Summary of Contents for T-6222

Page 1: ... the instructions in this manual to obtain the optimum resultsfrom this unit We also recommend that you keep this manual handyfor future reference OPERATION MANUAL PUBLIC ADDRESS SYSTEM ON OFF POWER CH FREQ BAND IR AM FM TUNER T 6222 ...

Page 2: ...FETY PRECAUTIONS 3 2 GENERAL DESCRIPTION 5 3 FEATURES 5 4 NOMENCLATURE AND FUNCTIONS 4 1 Front Panel 6 4 2 Rear Panel 6 4 3 Remote control 5 TUNER 8 6 APPLICATIONS 9 7 SPECIFICATIONS 10 8 DIMENSIONAL DIAGRAM 11 7 OPERATION 2 ...

Page 3: ...t in fire or electric shock Be sure to replace the unit s terminal cover after connection completion Because high voltage is applied to the speaker terminals never touch these terminals to avoid electric shock Be sure to ground to the safety ground earth terminal to avoid electric shock Never ground to a gas pipe as a catastrophic disaster may result Avoid installing or mounting the unit in unstab...

Page 4: ...g sooty smoke or steam as doing otherwise may result in fire or electric shock When the Unit is in Use Do not place heavy objects on the unit as this may cause it to fall or break which may result in personal injury and or property damage In addition the object itself may fall off and cause injury and or damage Make sure that the volume control is set to minimum position before power is switched o...

Page 5: ...r supply mode 3 the standard output 775mV music signal 4 built in 8 2W to monitor volume 5 LCD display buttons infrared operation 6 the microcomputer control light touch keys operation 7 1 road mono audio signal output 8 FM AM FM AM optional receive two band radio frequency memory storage can be up to 99 9 radio frequency automatic search storage function and can be power off memory function 10 Mo...

Page 6: ...g button up 6 Frequency up down adjustment button 7 POWER SWITCH On top of the opening Power Press the end power shut down 8 POWER Power indicator 6 ON OFF POWER CH FREQ BAND IR 5 6 4 2 REAR PANEL 9 AC POWER INPUT 10 AUDIO OUTPUT 11 MONITOR VOLUME 12 FM BAND 75 OHM ANTENNA 13 AM BAND ANTENNA 10 11 12 9 AUDIO OUTPUT R L MON VOL MIN MAX ANTENNA FM75 AM 13 ...

Page 7: ...keys 3 Last 4 frequency input 5 Radio auto manual switch button 6 Manual automatic mode button 7 Power button 8 On Off key 9 Radio button 10 AM FM conversion 11 Channel shift keying 12 Manual key 4 2 REAR PANEL 24V 9 AC POWER INPUT 10 DC 24V INPUT 11 AUDIO OUTPUT 12 MONITOR VOLUME 13 FM BAND 75 OHM ANTENNA 14 AM BAND ANTENNA 11 12 13 9 14 AUDIO OUTPUT R L MON VOL MIN MAX ANTENNA BATT SUPPLY 24V 2A...

Page 8: ... broadcast wave band As if show an t want to wave band invite press Wave band key stoke accept of wave band per Press once give switch fm am 3 Select broadcasting station means Auto tune show occasionally auto illumine Per press once auto Manual tune select key auto ma give switch 4 Select broadcast broadcasting station Press key up direction high end frequ ency search press key down direction low...

Page 9: ...LICATIONS REAR PANEL CONNECTIONS 9 MIXER AMPLIFIER AUX2 OUT AUX1 MIC2 MIC3 MUTE EMC INPUT MIC2 MIC3 LINE INPUT OUTPUT COM 4 16 70V 100V AM ANTENNA FM ANTENNA AUDIO OUTPUT R L MON VOL MIN MAX ANTENNA FM75 AM ...

Page 10: ...6222 TUNER TUNER 76 108MHz 520 1720kHz 20uV 6 0mV m 40dB 36dB FREQUENCY RESPONSE SENSITIVITY SIGNAL NOISE RATIO FM FM FM AM AM AM DIMENSION mm NET WEIGHT GROSS WEIGHT 484X350X44 POWER CONSUMPTION POWER REQUIREMENTS 220V 240V 50 60Hz 5Kg 3 8Kg 10VA 10 ...

Page 11: ...100 Over 100 Over Over 100 8 DIMENSIONAL DIAGRAM UNIT mm 6 44 41 350 44 50 436 484 UNIT mm 11 ON OFF POWER CH FREQ BAND IR AUDIO OUTPUT R L MON VOL MIN MAX ANTENNA FM75 AM ON OFF POWER CH FREQ BAND IR ...

Page 12: ...PUBLIC ADDRESS SYSTEM Version V0 1 ...