4
www.itec-audio.com
DIGIPOWER 2x500T
ITEC DIGIPOWER 2x500T - FRONT VIEW
10
9
8
7
6
1
2
3
4
5
1. 24V DC:
indicates that 24V DC power is applied
2. Channel 1 Fault:
indicates a fault, e.g.: thermal overload at channel 1
During normal operation this LED fl ashes shortly after powering up until the protection mode
is terminated and the speaker output is enabled.
3. Channel 1 Clip:
indicates an excessive input signal and the activation of the built-in limiter to prevent a clipping
of
the
signal
4. Channel 2 Fault:
as item 2, but for channel 2
5. Channel 2 Clip:
as item 3, but for channel 2
6. 230V AC:
indicates that the applied voltage is 230V AC. The device is supplied by this voltage -
the 24V DC remains unloaded.
7. Channel 1 Operating Mode:
Indicates that channel 1 is active. This means a signal at input 1 is present,
which is amplifi ed. If no signal is detected, the amplifi er switches to a low power
standby mode - the LED turns off.
8. Channel 1 Signal:
indicates that the signal is > 30dB.
9. Channel 2 Operating Mode:
as item 7, but for channel 2
10. Channel 2 Signal:
as item 8, but for channel 2