11
www.itec.com.pt
iFP 03®
13 | 03 | 2020
EN
EN
* User quantity:
100pcs password user, 150pcs Fingerprint user,800pcs card user
* System Initialization:
(Any fingerprint can open the door under the factory setting.) The default admin code is 12301230, you
must change the default admin code to add user. You can not add user with default admin code. If you want to return to the
factory setting, please follow the operation below.
Press “RESET” for 6 seconds
→
The system will return to the factory setting
System Setting:
The lock will enter the function settings by pressing “*”+ “#” ( or press “ RESET” on the lock back panel)
Functions
Operations
Instructions
1
Add admin code
1
→
input code
The NEW admin code will replace the old
one
2 Add user
2
→
input fingerprint
or code
Input fingerprint/card/code one by one
3 Delete individual user
3
→
1
→
U
U stands for User (input Code/Card/
fingerprint)
3 Delete all user
3
→
2
Delete all users except Admin
0
Passage mode setting 0
→
1
→
X
1-Start, 2-forbid, System default to be 2
Validation mode
settings
0
→
2
→
X
1-Single user, 2-Double user, System default
will be 1
Voice settings
0
→
3
→
X
1-Enable, 2-Disable, System default will be 1
1) Unlock function:
by Nr-Code,Card, Fingerprint or Mechanical key.
2) Low voltage alarm function:
There will be an alarm when you unlock the door if the voltage is below 4.8V. After that, the lock can still be unlocked for approx.
200 times.
3) Passage Function:
The lock will unlock automatically when in passage mode, after you press Code or fingerprint. You can open the door in the
Passage Mode without using a Code or fingerprint. The door will have a sound indication when the door is opened in “passage”
mode. If you press the keypad or fingerprint, the lock will END the “Passage” Mode.
4) Double User Verification Functions:
In the Double User Mode, there must be given two different user Codes or fingerprint to unlock the door. Combinations like
Code+Code or Code+fingerprint or fingfingerprint can be used. Admin code will always be except.
* ONLY Admin User can set a new Admin code by new system-setting (see above settings). After the revision, the new Admin
code will replace the old Admin-code immediately. (the new Admin-code will replace the old one)
* This lock has the “anti-peeking” function, with which users can input random number(s) before or/and after the real password,
e.g. XXX +paXXX. (max. 20 digits.)
* Code digits can be 6-10 digits. The system don’t allow you to program the same Code (same number) or fingerprint twice.
Summary of Contents for iFP 03
Page 3: ...3 www itec com pt iFP 03 13 03 2020 PT instalação instalação pilhas 1 3 1 2 2 ...
Page 9: ...9 www itec com pt iFP 03 13 03 2020 1 2 3 installation of the handle position EN ...
Page 13: ...13 www itec com pt iFP 03 13 03 2020 ES instalação baterías de instalación 1 3 1 2 2 ...
Page 19: ...19 www itec com pt iFP 03 13 03 2020 1 2 3 installation de la position de la poignée FR ...