Operation and Application
Copyright ©ITECH Electronic Co., Ltd.
36
2.
Set the voltage and frequency parameters in the sweep interface.
Parameters in the sweep interface are described as follows:
Parameter
Explain
Start voltage
Set the starting voltage.
Stop voltage
Set the ending voltage.
Step Voltage
Set the step voltage.
Start freq
Set the starting frequency.
Stop freq
Set the ending frequency.
Step freq
Set the step frequency.
Step time
Set the step time.
Mode
Set the sweep mode.
Time: Time Sweep Mode
Trig: Trigger mode
Priority
Priority setup
Volt-Priority
Freq-priority
Volt&Freq
Waveform
Select sweep waveform
Sine
Square
Sawtooth
Triangle
Trapezoid
Finish
Set the running state after the sweep
execution is finished:
• off: Directly off the output after the
execution is finished;
• Last: Keep the last waveform unchanged
after the execution is finished.
Normal: return to normal mode after the
sweep execution is finished.