Configuration Arbitrary Waveform
Copyright ©ITECH Electronic Co., Ltd.
70
Chapter7
Configuration Arbitrary Waveform
This chapter will introduce configuration of arbitraryny waveform of IT7800.
Besides the five standard waveforms (see 4.3 Waveform Selection ) built in the
main interface, the user can enable the outputting of AC wave sequences of
different amplitudes through List and self-define function.
The list function is not supported in multi-channel mode.
7.1 List Function
at maximum of 200 steps can be edited for each List file. The user can choose
any waveform from existing 11 waveforms. Or, the user can choose a waveform
file stored in the device through self-define function (see 8.3 “Self-defined
Waveform Function” for details) and combine the waveform files into a List file
based on required order. Meanwhile, the user can set the starting steps of the
List file, run count and end state of the waveform, and edit parameters such as
frequency, amplitude, running time and rising slope of each waveform.
7.1.1 Create a new List file
Create a new single-phase List file
Under single-phase mode, the user can output AC waveform sequences with
different amplitudes by creating a new List file. Detailed operation steps are as
below:
1.
Press [Shift]+[V-set](
list
) on the front panel to enter the List function
configuration interface, as shown in the figure below.
888.csv: the list file name to execute.
Trig source: select the trigger source
Run/Stop: Run/stop the list function.
Open: Select the List file to execute.