Function
and Features
Copyright ©ITECH Electronic Co., Ltd.
19
Von
VOLTAGE ON
Start judgment voltage of load
Living
Von living state
Point= 2V
Set Von point
Latch
Von latch state
Point= 2V
Set Von point
Protect
PROTECT MENU
Max-P
Set hardware power protection
MAX POWER
Point=300.00W
Set hardware protective power value
A-Limit
Set software current protection
CURRENT LIMIT
On
Start function
Point=15A
Set software current protective value
Delay= 3S
Set software current protective delay
Off
Stop function
P- Limit
Set software power protection
POWER LIMIT
Point=300W
Set software power protective value
Delay= 3S
Set software power protective delay
Time
Set loaded timer
ON-TIMER
On
Enable timer function
Delay=10S
Setup timing,max value is 60000s
Off
Disable timer function
Measure
MEASURE MENU
TimeV1
Measure voltage rise/drop time
TIMER VOLTAGE1
Set starting voltage value
Point=0.000V
TimeV2
Measure voltage rise/drop time
TIMER VOLTAGE2
Set stopping voltage value
Point=120.00V
FILTER
Smoothing function
Average Count=2^(2~16)
Set of average count
Remote-Sense
REMOTE SENSE STATE
Remote sense function
On
Enable remote sense function
Off
Disable remote sense function
Ext-Program
EXTNAL PROGRAM
External analog control function
On
Turn on external analog control function(0-10V)
Off
Turn off external analog control function(0-10V)
3.9
Trigger function
Trigger function is necessary to operate dynamic pulse output and list output.
There are five triggering methods to trigger the tested instrument.
Optional triggering sources of triggering function of electronic load comprise:
⚫
Key (
(Shift)+
(Trigger)) trigger: when key trigger is valid, press
(Shift)+
(Trigger) key and the load will trigger an operation.
⚫
External trigger signal (TTL): TRIG on the rear board is the triggering input
terminal. When external trigger signal method is effective, after applying a
low pulse (> 10 us), the load will trigger an operation. When external trigger
is selected, the positive and negative terminals of TRIG will generate
trigger signals and low pulse is effective. An input corresponding to each
trigger can be used to change set value (voltage, current, resistance, etc).