Important Safety Warning 

(SAVE THESE INSTRUCTIONS) 

 

CAUTION! 

To prevent the risk of fire or electric shock, install in a temperature and 

humidity controlled indoor area free of conductive contaminants. (See the specifications 
for the acceptable temperature and humidity range.) 

CAUTION! 

To reduce the risk of overheating the UPS, do not cover the UPS' cooling vents 

and avoid exposing the unit to direct sunlight or installing the unit near heat emitting 
appliances such as space heaters or furnaces. 

CAUTION! 

Do not attach non-computer-related items, such as medical equipment, 

life-support equipment, microwave ovens, or vacuum cleaners to UPS. 

CAUTION! 

Do not plug the UPS input into its own output. 

CAUTION!

 Do not allow liquids or any foreign object to enter the UPS. Do not place 

beverages or any other liquid-containing vessels on or near the unit.   

CAUTION!

 In the event of an emergency, press the OFF button and disconnect the power 

cord from the AC power supply to properly disable the UPS. 

CAUTION! 

Do not attach a power strip or surge suppressor to the UPS. 

CAUTION! 

With the installation of this equipment, it should be prevented that the sum of 

the leakage current of the UPS to the connected consumer exceeds 3.5mA. 

Attention

 hazardous through electric shock. Also with disconnection of this unit from the 

mains, hazardous voltage still may be accessible through supply from battery. The battery 
supply should be therefore disconnected in the plus and minus pole at the quick 
connectors of the battery when maintenance or service work inside the UPS is necessary. 

CAUTION! 

Servicing of batteries should be performed or supervised by personnel 

knowledgeable of batteries and the required precautions.    Keep unauthorized personnel 
away from batteries.   

CAUTION! 

When replacing the batteries, use the same number and type of batteries. 

CAUTION! 

Internal battery voltage is 12VDC. Sealed, lead-acid, 6-cell battery. 

CAUTION! 

Do not dispose of batteries in a fire. The battery may explode. Do not open or 

mutilate the battery or batteries. Released electrolyte is harmful to the skin and eyes. 

CAUTION!

 Unplug the UPS prior to cleaning and do not use liquid or spray detergent. 

CAUTION! 

A battery can present a risk of electric shock and high short circuit current. 

The following precaution should be observed before replacing batteries: 
1) 

Remove watches, rings, or other metal objects. 

2) 

Use tools with insulated handles. 

3) 

Wear rubber gloves and boots. 

4) 

Do not lay tools or metal parts on top of batteries. 

5) 

Disconnect charging source prior to connecting or disconnecting batteries terminal. 

Summary of Contents for GenPower 636

Page 1: ...GenPower 636 848 Offline UPS www itek it Startup Manual...

Page 2: ...3 Trouble Shooting 4 Specification 5 Thank you for purchasing this UPS To safely operate this uninterruptible power supply system please read and follow all instructions carefully Read this manual th...

Page 3: ...nnected consumer exceeds 3 5mA Attention hazardous through electric shock Also with disconnection of this unit from the mains hazardous voltage still may be accessible through supply from battery The...

Page 4: ...items inside of package UPS Unit Quick Guide Overview Front Panel Overview Power Switch UPS status indicator Fault Battery status indicator Check the Indicator Alarm Table for the details Rear Panel...

Page 5: ...ty is outside the specific limits Please check the specs for the limitations Connect to Utility and Charging Plug in the AC input cord to the wall outlet For the best results suggest to charge the bat...

Page 6: ...ed in the specs UPS fault Return the unit to the service center Alarm sounds every 2 seconds when the mains is normal Battery defect Replace the battery with the same type of battery Charging board is...

Page 7: ...uency 50 Hz or 60 Hz OUTPUT Voltage Regulation 10 Transfer Time Typical 2 6 ms Waveform Simulated Sine Wave BATTERY Type Number 12 V 7 AH x 1 12 V 9 AH x 1 Charging Time 8 hours recover to 90 capacity...

Page 8: ...EN...

Page 9: ...GenPower 636 848 Offline UPS www itek it Manuale base...

Page 10: ...oblemi 4 Specifiche 5 Grazie per aver acquistato un UPS Affinch questo sistema di alimentazione ininterrotta funzioni correttamente leggere e seguire attentamente tutte le istruzioni Prima di disimbal...

Page 11: ...e di dispersione del gruppo di continuit per il consumatore collegato sia superiore a 3 5 mA Attenzione rischio di scosse elettriche Anche dopo aver disconnesso l unit dall alimentazione a corrente lo...

Page 12: ...ramica Panoramica del pannello anteriore Interruttore di alimentazione Indicatore di stato dell UPS Indicatore di stato della batteria errore Verificare la tabella degli indicatori ed allarmi per magg...

Page 13: ...zzarla la prima volta Quando connesso al dispositivo l UPS carica la sua batteria Collegamento dei carichi Collegare i carichi alle prese in uscita sul pannello posteriore dell UPS Sar sufficiente acc...

Page 14: ...ria dell UPS Portare l unit al centro di assistenza Allarme acustico ogni 2 secondo quando l alimetazione di rete normale Batteria diffettosa Sostituirla con un altra dello stesso tipo La scheda di ri...

Page 15: ...azione di tensione 10 Tempo di trasferimento Tipico 2 6 ms Forma d onda Onda sinusoidale simulata BATTERIA Tipo e numero 12 V 7 AH x 1 12 V 9 AH x 1 Tempo di carica 8 ore per recuperare il 90 di capac...

Reviews: