41
Bicycle detection active in the vehicle lane
Note:
TIMING – The Extend, Delay, and Pulse zones all have user programmable timing. To set the
timing for these zone types, either click both left and right mouse buttons simultaneously, or push
the middle mouse button. The third mouse button may be the mouse wheel on some types of
Vantage compatible mice. When this is done, the timing parameter of the zone type is highlighted.
Now, by left or right clicking the mouse buttons, you will scroll through a set of timing values in
tenths of a second from 1 to 250. When the desired timing value is reached, either click both left and
right mouse buttons simultaneously or click the middle mouse button to set your timing choice.
4.1
Drawing Zones
The first step in drawing a Vantage detection zone is to press and hold the menu button for two or more
seconds and then release it; this brings up the main menu bar. Next, move the mouse cursor to the "Add"
option and left click the mouse to select it. The last step is to set the various zone parameters and then select
"Exit" to start drawing the detection zone.
At this point a "Place Corner" prompt is seen on the screen and the cursor is visible and can be freely moved
around on the screen. The corners of the zone that you are about to draw must be anchored in place by
clicking the left mouse button. Place the cursor where you want the back top left corner of the new zone to
be located and left click the mouse to anchor it in place, then place the cursor where you want the top right
back corner of the new zone and repeat this same process. You will be placing each detection zone corner in
a clockwise pattern. The next corner to place and anchor in place will be the bottom right corner and the last
Summary of Contents for VersiCam
Page 1: ...Part Number 493432201 Rev F ...
Page 13: ...User Guide 13 2 1 Menu Tree ...
Page 30: ...User Guide 30 ...
Page 77: ...User Guide 77 10 TECHNICAL INFORMATION IMSA 39 2 40 2 Cable ...
Page 79: ...User Guide 79 VersiCam Specification Sheet ...
Page 80: ...User Guide 80 Phase Information ...
Page 81: ...User Guide 81 Detector Rack Configurations ...
Page 83: ...User Guide 83 ...
Page 84: ...1700 Carnegie Avenue Santa Ana CA 92705 Phone 949 270 9400 Fax 949 270 9401 ...