background image

16

 

 

2.6. Product card information

 

 

Itho Daalderop

 

CVE-S ECO

 

Description

 

Symbol

 

Unit

 

S

 

H

 

Specific energy consumption class

 

 

 

D

 

Specific energy consumption, under moderate

 

climate conditions

 

SEC

 

kWh/(

m2

.a)

 

-20

 

-20

 

Specific energy consumption, under warm

 

climate conditions

 

SEC

 

kWh/(

m2

.a)

 

-8

 

-8

 

Specific energy consumption, under cold

 

climate conditions

 

SEC

 

kWh/(m2.a)

 

-41

 

-41

 

Type of ventilation unit

 

VE

 

 

Residential ventilation unit (RVE)

 

One-way ventilation unit (EVE)

 

Type of drive

 

 

 

Variable speed

 

Type of heat recovery system

 

HRS

 

 

None

 

Thermal efficiency of heat recovery

 

ƞt

 

%

 

Not applicable

 

Maximum flow rate

 

qmax

 

m3/h

 

375

 

415

 

Electrical input power of the fan drive,

 

at maximum flow rate

 

Pmax

 

W

 

50

 

62

 

Sound power level

 

LWA

 

dB

 

50

 

52

 

Reference flow rate

 

qref

 

m3/s

 

0,070

 

0,080

 

Reference pressure difference

 

ΔPref

 

Pa

 

50

 

Specific input power

 

SPI

 

W/(

m3/h

)

 

0,078

 

0,088

 

Ventilation control

 

 

 

Manual control (no DCV)

 

Control factor

 

CTRL

 

 

0,85

 

Summary of Contents for 03-00398

Page 1: ...Installation use Itho Daalderop CVE S ECO D...

Page 2: ...Original document...

Page 3: ...initions are used in this manual to draw attention to dangers instructions or directions relating to persons product installation and or environment Note Instruction relevant to the installation opera...

Page 4: ...ght to change products and manuals without prior notice Due to our continuous process of improving our products this document may differ from the product delivered to you You can download the latest v...

Page 5: ...card information 16 2 7 Improve energy label 18 2 8 Recycle 18 3 Installation 19 3 1 Installing the ventilation unit 19 3 2 Connecting electrically 20 4 Operation 22 4 1 Subscribe and unsubscribe RF c...

Page 6: ...ith the instructions in the manual Only accessories and parts as prescribed by the manufacturer may be used Do not use the product for purposes other than those for which it is intended as described i...

Page 7: ...e and are aware of the dangers of the product and or system Cleaning and maintenance by the user must not be carried out by children or by persons with reduced physical sensory or mental capabilities...

Page 8: ...he power supply wait at least 10 seconds before opening or touching the product as these parts will continue to rotate for some time Secure the system against unintentional reactivation Maintenance in...

Page 9: ...of the product Take care not to damage the electrical circuit Do not use the appliance to vacuum water boilers heating systems etc Make sure that the appliance drains into a drain that is suitable an...

Page 10: ...tion complies with the legal requirements the regulations contained in this document and other applicable documentation from the manufacturer All legal requirements and regulations are subject to addi...

Page 11: ...tilates several rooms in the house Through channels the kitchen bathroom toilet and if necessary the storage storage room can be accessed laundry room connected to the unit for air extraction A motorl...

Page 12: ...12...

Page 13: ...r Base 2 3 Accessories Article Type Description 03 00062 Spider Base Climate thermostat 04 00045 RFT CO2 230V RFT CO2 sensor with actuator 230 V power supply 04 00046 RF RV BAT RFT RV sensor with cont...

Page 14: ...eight kg 3 4 CONNECTIONS Connections from home mm 4x 124 Connection to the outside mm 1x 124 GENERAL IP classification IP31 RF integrated 30 m free field 868 MHz Supply voltage 230V 50Hz Power connect...

Page 15: ...0 18 7 Setting 3 maximum 375 100 50 Type H Capacity m3 h Pressure Pa Power W Setting 1 minimum 25 5 1 6 Stand 1 standard 75 11 2 5 Setting 1 maximum 125 31 5 2 Position 2 standard 175 60 10 2 Setting...

Page 16: ...1 41 Type of ventilation unit VE Residential ventilation unit RVE One way ventilation unit EVE Type of drive Variable speed Type of heat recovery system HRS None Thermal efficiency of heat recovery t...

Page 17: ...Not applicable Instructions for pre assembly disassembly www ithodaalderop nl Sensitivity of airflow to pressure fluctuations at 20 Pa and 20 Pa Not applicable Airtightness between inside and outside...

Page 18: ...ordance with government regulations In order to comply with the obligation to separate the treatment of batteries and electrical household appliances the product bears the symbol of a crossed out dust...

Page 19: ...raction of air to the outside and four outlets for the extraction of exhaust air from the house B a Connect the outlet spigot 1 diameter 124 mm to the exhaust duct roof outlet to the outside b Connect...

Page 20: ...following diagrams and table b If necessary clamp the power cord into the terminals on the underside of the unit 3 2 1 Connection with Euro plug The SE and HE versions of the unit are equipped with a...

Page 21: ...nd Functie Connection W green yellow earth mains power N blue zero mains power L1 brown low solid state mains supply switch L2 grey middle car link switch unit L3 black high link switch unit N L1 L3 L...

Page 22: ...22 ithodaalderop 4 Operation 1 2 3 Q 0 4 5 6 0 J 000 S...

Page 23: ...d Off RF Controls on page 25 You can register up to 20 wireless products controls and or sensors The ventilation unit can be set to one of the following positions as required Position 1 low position w...

Page 24: ...ch on the Auto Night position press the Auto button twice on the wireless control switch or controllable sensor The Auto Night setting cannot be set using the wired three position switch Note If sever...

Page 25: ...in the vicinity of the ventilation unit a Disconnect the power supply wait 15 seconds and revive the ventilation unit b Press the four buttons of the control switch simultaneously within two minutes T...

Page 26: ...en External and internal doors must be closed There must be sufficient flow through space under the inner doors The adjustable valves must be fully open in all rooms Go through the following steps to...

Page 27: ...within its range so that it is possible that another RF controller or RF sensor may be logged on to your ventilation unit undesirably As a result your ventilation unit responds not only to your own R...

Page 28: ...ere are two potmeters for adjusting the minimum and maximum capacity or low and high level Whether these capacities have to be adjusted Tip If the capacity has to be increased first try to open the ai...

Page 29: ...tiometer H Highlight Default setting Setting range Min Max CVE S ECO S 225 m3 h 175 m3 h 375 m3 h CVE S ECO H 275 m3 h 175 m3 h 415 m3 h 5 1 2 Adjusting low setting CVE S ECO If necessary adjust the l...

Page 30: ...exterior of the unit with a slightly damp cloth a Regularly inspect the unit for abnormal noises b Regularly check that the unit responds to the hand controls c Check regularly that the unit responds...

Page 31: ...ventilation unit back under tension If the appliance makes abnormal noises the fan is swaying or is seriously dirty it must be replaced or cleaned 6 1 3 Inspection RF control Regularly check that the...

Page 32: ...ery is empty the control switch no longer functions and the ventilation unit no longer responds to manual operation The battery type CR2032 3V must then be replaced Incorrect placement of the battery...

Page 33: ...ely from the canal a Remove the foam sealing tape b Completely immerse the valves in a solution of a mild detergent e g dish soap or all purpose cleaner If necessary the valves can be cleaned in the d...

Page 34: ...e installer a Disconnect the ventilation unit from the power supply b Dismantle the lid as mentioned in Setting high and low c Loosen the motor plate by unlocking the clamping lugs in the three slots...

Page 35: ...n on the impeller f In case of severe soiling it is advisable to clean the RH sensor and the housing around it A also with a soft brush To do this remove the circuit board from the housing g If necess...

Page 36: ...36 3 5 2 6 7 4 1 7 Service parts Please check our website for the latest information on the service components...

Page 37: ...CAP BLACK Plastic cap black 4 545 5118 UK 1500 E Power cable Euro plug 4 545 5117 UK 1500 P Power cable Perilex plug 5 545 5206 M W CVE ECO con Engine impeller CVE ECO connector 6 05 00492 CVE S PCB S...

Page 38: ...to a wall socket b There is no voltage at the socket outlet Restore the voltage at the wall socket Use a different wall socket c The fan is running on stable due to extreme contamination Clean the fan...

Page 39: ...the RF control if the wireless signal is affected by the presence of many steel obstacles c The printout of the ventilation unit is defective Replace the PCB and feed the Commissioning procedure again...

Page 40: ...ed on to the fan Start the IBS procedure again and log on the RF control Move the RF control if the wireless signal is affected by the presence of many steels obstacles d RF control is defective Repla...

Page 41: ...diagram d The printout of the ventilation unit is defective Replace the PCB and feed the Commissioning procedure again The fan suddenly turns much faster or softer for no apparent reason Cause Solutio...

Page 42: ...tically switches the ventilation unit to a higher position c Movement has been detected by the PIR sensor which automatically switches the ventilation unit to a higher position d The RF control of an...

Page 43: ...report the RF sensor e The distance between the ventilation unit and the RF sensor is too great or the signal encounters too many obstacles Please try to register again If this does not work move the...

Page 44: ...switches the ventilation unit to a higher position d The ventilation unit has been switched to another position by means of a wireless control e A wireless control or sensor of an adjoining house is...

Page 45: ...ee conditions See the product page on our website for full warranty terms and or additional warranty terms or conditions If there are any problems with the operation of our product we advise the consu...

Page 46: ...laid down in the directives R pond aux exigences des directives Entspricht den Anforderungen in den Richtlinien Complies with the requirements stated in the directives Low Voltage Directive 2014 35 EU...

Page 47: ...nised European standards Replies to the harmonised European standards Complies with the harmonised European standard AND 60335 1 2012 AND 60335 2 80 2003 A1 2004 AND 60335 2 80 2003 A2 2009 AND 60730...

Page 48: ...erstraat 2 3115 HB Schiedam E idsupport ithodaalderop nl I www ithodaalderop nl Consult your installer if you have any questions If you do not know the installer please visit www ithodaalderop nl deal...

Reviews: