19
3.
Installation
3.1.
Installing the ventilation unit
Attach the ventilation unit, preferably in a closed room,
with the appropriate screws and the mounting holes to a
(sloping) wall or ceiling/floor with sufficient load-bearing
capacity (> 200 kg/m2). (A)
The ventilation unit is equipped with five air outlets: one
outlet for the extraction of air to the outside and four
outlets for the extraction of exhaust air from the house. (B)
a)
Connect the outlet spigot (1, diameter 124 mm) to
the exhaust duct / roof outlet to the outside.
b)
Connect the suction nozzles (1-4, diameter 124
mm) to the ducts leading to the rooms to be
evacuated.
c)
Close unused spouts on the unit with the
blue caps provided.
B
A
ä
Warning!
When the unit is used in a stacked construction, a
mechanical non-return damper must be fitted in the
discharge duct to prevent backflow from the central
duct.