TEMP - Heater temperature
The maximum temperature of the heater's water.
Min. 55°C | Max. 80°C | +/- 5°C.
●
65°C [standard setting]
BOOST
There may occasionally be an insufficient amount of hot water.
Activate the BOOST function for immediate one-time heating of the
water to at least 85°C.
After the water has been heated, the heater will revert to the
CONFIGURATION
settings.
●
ON
The water is heated once and immediately to at least 85°C.
●
OFF [standard setting]
The BOOST function is disabled and the water is heated in
accordance with the
CONFIGURATION
settings.
The BOOST function is enabled in ON mode alongside the SMART
CONTROL and DAY/NIGHT functions.
NIGHT - Day/night
In case of variable rate electricity tariffs, you can use the DAY/
NIGHT function to only heat the water during off-peak hours.
In night mode the heater automatically determines when to start
heating for the correct water temperature at the end of the night.
●
ON
Day and night modes are activated by setting the times in the
TIME
service menu.
-
Day mode - The water is NOT heated during this period.
-
Night mode - The water CAN be heated during this period.
●
OFF [standard setting]
The DAY/NIGHT function is disabled and the water is heated in
accordance with the
CONFIGURATION
settings.
The DAY/NIGHT function is disabled by activating the SMART
CONTROL function.