Steam is coming out of the mixer tap.
Cause
Solution
a)
The thermostat or overload circuit breaker
is faulty.
●
Disconnect the appliance from the
mains power.
Contact your installer or service
organisation.
The heater is causing a short circuit
Cause
Solution
a)
There is a short circuit in the electrical
wiring or the heater element.
●
Disconnect the appliance from the
mains power.
Contact your installer or service
organisation.
No expansion water is coming out of the safety group
Cause
Solution
a)
Defective safety group.
●
Disconnect the appliance from the
mains power.
Replace the safety group.
b)
No water in the heater.
●
Fill the heater with water.
c)
The heater is OFF (standby) [dependent on
model].
●
Switch the heater ON.
d)
The heater has encountered an error.
●
The heater must be reset.
e)
Heating element is broken.
●
Disconnect the appliance from the
mains power.
Contact your installer or service
organisation.