Regency
®
Model 4724 Control Expander Installation Manual (P/N 150596-02, Rev. A)
Revised 8/98
40
ARS#1_ _ _ _ _ _ _ _
Select the areas to be accessed by Touchpad 1.
NOTE
When a panic key is pressed on a touchpad, all areas controlled by that touchpad go into
alarm.
INTERCOM#1:NO
This option enables the Intercom Function for Touchpad 1.
NOTE
Do NOT select the Door option on an intercom station, as this would disable the
TEL
key.
DOOR#1:NO
When this option is selected, door access can be gained by entering a secret code on Touchpad
1.
NOTE
On some touchpad models, the Door and Intercom options are not available together. It is pos-
sible to select
NO
for both options.
HIGH SEC#1:NO
When this option is selected, the High Security Code must be entered in addition to the secret
code to gain door access.
DOOR ONLY#1:NO
When this option is selected, Touchpad 0 can be used only for door access, not for other func-
tions, such as arming and disarming.
STATION:#2
Select the next touchpad for which options are to be programmed (up to 15 touchpads).
8.14 Key Zones (Menu 13)
STATION:#0
Select the touchpad for which the panic key zones are to be programmed (0-15 touchpads).
NOTE
Station 0 options are not used. Begin programming with Station 1.
KEY:UNUSED
Select the panic key for which you want to program options. Although the display shows
KEY:UNUSED there is no “unused” key. Instead, you must select a panic key. Select
1
for the
POL,
2
for the AUX key, and
3
for the FIRE key.
TYPE:
Select a zone type for the key you specified in the last step. Enter the number shown next to the
appropriate zone type in Table 12.