5
Òàáëèöà
/ Table 1 –
Òåõíè÷åñêèå
ïàðàìåòðû
áëîêîâ
ñ
ìîíèòîðèíãîì
ñåðèè
ADMIN / Technical
parameters of units of ADMIN series with monitoring
Íàèìåíîâàíèå ïàðàìåòðà / Parameter denomination
Çíà÷åíèå äëÿ òèïîèñïîëíåíèÿ
PV
1212 /
Value
for
PV
1212
version
Çíà÷åíèå äëÿ òèïîèñïîëíåíèÿ
PV
1213 /
Value
for
PV
1213
version
AN-PM13-24-
18C13-06C19-41
AN-PM13-24-
21C13-03C19-41
AN-PM13-42-
36C13-06C19-41
AN-PM13-36-
24C13-12C19-43
AN-PM13-42-
36C13-06C19-43
Ôàçà/Phase
1
3
Íîìèíàëüíîå íàïðÿæåíèå íà ôàçó, Â /
Rated
voltage
per
phase
,
V
250
×àñòîòà òîêà, Ãö / Current frequency, Hz
50
Íîìèíàëüíûé òîê íà ôàçó, À /
Rated
current
per
phase
, À
32
Ìàêñèìàëüíàÿ ìîùíîñòü íàãðóçêè, Âò /
Maximum
load
power
,
W
7 360
22 000
Íîìèíàëüíûé òîê ðîçåòêè, À / Rated current of socket, À
1
0
16
1
0
16
1
0
16
1
0
16
1
0
16
Êîëè÷åñòâî ðîçåòîê, øò. /
Socket
quantity
,
pcs
18
6
21
3
36
6
24
12
36
6
Òèï ðîçåòêè ïî
/ Type of sockets according
to
IEC 60320-1
Ëèñò/
Sheet
Ñ13
Ëèñò/
Sheet
Ñ19
Ëèñò/
Sheet
Ñ13
Ëèñò/
Sheet
Ñ19
Ëèñò/
Sheet
Ñ13
Ëèñò/
Sheet
Ñ19
Ëèñò/
Sheet
Ñ13
Ëèñò/
Sheet
Ñ19
Ëèñò/
Sheet
Ñ13
Ëèñò/
Sheet
Ñ19
Âèä ðîçåòêè / Type of socket
2Ð+ÐÅ
Âèä âèëêè / Type plug
2Ð+ÐÅ
3Ð+N+ÐÅ
Òèï âèëêè / Plug type
Ñòàíäàðòíûé ëèñò
/ Standard sheet
2-
II
ïî
IEC
60309-2
Ìàòåðèàë êîðïóñà áëîêà / Material of unit body
Ñòàëü /
Steel
Äëèíà êàáåëÿ, ì / Cable length, m
3
2
Ñå÷åíèå ïðîâîäíèêîâ ãèáêîãî êàáåëÿ, ìì , íå ìåíåå /
2
Cross section of conductors of flexible cable, mm ,
minimum
3
ґ
6
5
ґ
6
Öâåò
/Colour
RAL 9005 (÷¸ðíûé
/
black)
Êëàññ çàùèòû îò ïîðàæåíèÿ ýëåêòðè÷åñêèì òîêîì ïî
ÃÎÑÒ 12.1.019 / Electric shock protection class
I
Çàùèòà îò ïåðåãðóçêè (àâòîìàòè÷åñêèå âûêëþ÷àòåëè) /
Overload
protection
(
circuit
breakers
)
2
ґ
16À
6
ґ
16À
Ñòåïåíü çàùèòû ïî ÃÎÑÒ 14254 (IEC 60529) / Degree of
protection according to IEC 60529
IP20
Òåìïåðàòóðà ýêñïëóàòàöèè /
Operating temperature
Îò 0
°
Ñ äî ïëþñ 45
°
Ñ /
From
0
°
Ñ
to
plus
45
°
Ñ
íà
ýêðàí
áëîêà
/ Measurement parameters for displaying
information on the unit display
Ïàðàìåòðû èçìåðåíèÿ äëÿ âûâîäà èíôîðìàöèè
Êîýôôèöèåíò ìîùíîñòè,
PF
/
Power
factor
,
PF
Íàïðÿæåíèå, Â /
Voltage
,
V
Êîëè÷åñòâî ïîòðåáëÿåìîé ýíåðãèè, êÂò·÷ / Ð
ower
requirement
,
kW
·
h
Òîê, À / Ñ
urrent
, À
Ìîùíîñòü, êÂò / Ð
ower
,
kW
Óäàëåííûé
ìîíèòîðèíã
ïàðàìåòðîâ
áëîêà
/ Remote
monitoring of unit parameters
Ïîëîæåíèÿ
ãëàâíûõ
êîíòàêòîâ
àâòîìàòè÷åñêîãî
âûêëþ÷àòåëÿ
(
âêëþ÷åí
/
âûêëþ÷åí
) /
Ð
osition of the main
contacts of the circuit breaker (on/off)
Íàïðÿæåíèå
,
òîê
è
êîýôôèöèåíò
ìîùíîñòè
êàæäîé
ðîçåòêè
/ Voltage, current and power factor of each
socket
Îêðóæàþùàÿ
ñðåäà
â
ñòîéêå
(
øêàôó
) –
âëàæíîñòü
/
òåìïåðàòóðà
(
ïðè
ïîäêëþ÷åíèè
âíåøíåãî
äàò÷èêà
òåìïåðàòóðû
/
âëàæíîñòè
) /
Å
nvironment in the rack (cabinet)
–
humidity/temperature (when connecting an
external temperature / humidity sensor)
Íàïðÿæåíèå, Â /
Voltage
,
V
Òîê, À / Ñ
urrent
, À
Êîýôôèöèåíò ìîùíîñòè,
PF
/
Power
factor
,
PF
Ìîùíîñòü, êÂò / Ð
ower
,
kW
Êîëè÷åñòâî ïîòðåáëÿåìîé ýíåðãèè, êÂò·÷ / Ð
ower
requirement
,
kW
·
h
Óäàëåííûé äîñòóï / Remote access
Óäàëåííûé
äîñòóï
÷åðåç
TCP/IP
è
âñòðîåííûé
10/100 Ethernet
ïîðò
/ Remote access via TCP /
IP and built-in 10/100 Ethernet port
Ïîääåðæêà
SNPM V1, V2
è
V3 / SNPM V1, V2 and V3 support
Ïîääåðæêà
ïðîòîêîëà
ñåòåâîé
ñâÿçè
,
âêëþ÷àÿ
TCP/IP, TELNET, SSL, SMTP, DHCP, SNTP
è
DNS / Network
communication protocol support, including TCP/IP, TELNET, SSL, SMTP, DHCP, SNTP
è
DNS
Ïîääåðæêà
Modbus RTU / Modbus RTU support
Summary of Contents for ADMIN AN-PM13-24-18C13-06C19-41
Page 12: ...12 Figure 7...
Page 13: ...13 Figure 8...
Page 14: ...14 Figure 9 Figure 10...
Page 15: ...15 Figure 11 Version 2...