6
Òàáëèöà
/ Table 2 –
Òåõíè÷åñêèå
ïàðàìåòðû
áëîêîâ
ñ
îáùèì
ìîíèòîðèíãîì
ñåðèè
ADMIN /
Technical parameters of units of ADMIN series with general monitoring
Íàèìåíîâàíèå ïàðàìåòðà /
Parameter denomination
Çíà÷åíèå äëÿ òèïîèñïîëíåíèÿ
PV
1412 /
Value
for
PV
1412
version
Çíà÷åíèå äëÿ òèïîèñïîëíåíèÿ
PV
1413 /
Value
for
PV
1413 version
AN-PM
3
3-24-
18C13-06C19-41
AN-PM
3
3-24-
21C13-03C19-41
AN-PM
3
3-42-
36C13-06C19-41
AN-PM
3
3-36-
24C13-12C19-43
AN-PM
3
3-42-
36C13-06C19-43
Ôàçà/
Phase
1
3
Íîìèíàëüíîå íàïðÿæåíèå íà ôàçó, Â /
Rated
voltage
per
phase
,
V
250
×àñòîòà òîêà, Ãö / Current frequency, Hz
50
Íîìèíàëüíûé òîê íà ôàçó, À /
Rated
current
per
phase
, À
32
Ìàêñèìàëüíàÿ ìîùíîñòü íàãðóçêè, Âò /
Maximum
load
power
,
W
7 360
22 000
Íîìèíàëüíûé òîê ðîçåòêè, À /
Rated current of socket, À 1
0
16
1
0
16
1
0
16
1
0
16
1
0
16
Êîëè÷åñòâî ðîçåòîê, øò. /
Socket
quantity
,
pcs
18
6
21
3
36
6
24
12
36
6
Òèï ðîçåòêè ïî
/ Type of sockets according
to
IEC 60320-1
Ëèñò/
Sheet
Ñ13
Ëèñò/
Sheet
Ñ19
Ëèñò/
Sheet
Ñ13
Ëèñò/
Sheet
Ñ19
Ëèñò/
Sheet
Ñ13
Ëèñò/
Sheet
Ñ19
Ëèñò/
Sheet
Ñ13
Ëèñò/
Sheet
Ñ19
Ëèñò/
Sheet
Ñ13
Ëèñò/
Sheet
Ñ19
Âèä ðîçåòêè / Type of socket
2Ð+ÐÅ
Âèä âèëêè
/
Type plug
2Ð+ÐÅ
3Ð+N+ÐÅ
Òèï âèëêè /
Plug type
Ñòàíäàðòíûé ëèñò
/ Standard sheet
2-
II
ïî
IEC
60309-2
Ìàòåðèàë êîðïóñà áëîêà / Material of unit body
Ñòàëü /
Steel
Äëèíà êàáåëÿ, ì /
Cable length, m
3
2
Ñå÷åíèå
ïðîâîäíèêîâ
ãèáêîãî
êàáåëÿ
,
ìì
,
íå
ìåíåå
/
2
Cross section of conductors of flexible cable, mm , minimum
3
ґ
6
5
ґ
6
Öâåò
/Colour
RAL 9005 (÷¸ðíûé
/
black)
ïî ÃÎÑÒ 12.1.019 /
Electric
shock
protection
class
Êëàññ çàùèòû îò ïîðàæåíèÿ ýëåêòðè÷åñêèì òîêîì
I
Çàùèòà îò ïåðåãðóçêè (àâòîìàòè÷åñêèå âûêëþ÷àòåëè) /
Overload
protection
(
circuit
breakers
)
2
ґ
16À
6
ґ
16À
Ñòåïåíü çàùèòû ïî ÃÎÑÒ 14254 (IEC 60529) / Degree of
protection according to IEC 60529
IP20
Òåìïåðàòóðà ýêñïëóàòàöèè /
Operating temperature
Îò 0
°
Ñ äî ïëþñ 45
°
Ñ /
From
0
°
Ñ
to
plus
45
°
Ñ
Ïàðàìåòðû èçìåðåíèÿ äëÿ âûâîäà èíôîðìàöèè
íà
ýêðàí
áëîêà
/ Measurement parameters for displaying
information on the unit display
Ìîùíîñòü, êÂò / Ð
ower
,
kW
Íàïðÿæåíèå, Â /
Voltage
,
V
Êîýôôèöèåíò ìîùíîñòè,
PF
/
Power
factor
,
PF
Òîê, À / Ñ
urrent
, À
Êîëè÷åñòâî ïîòðåáëÿåìîé ýíåðãèè, êÂò·÷ / Ð
ower
requirement
,
kW
·
h
Óäàëåííîå óïðàâëåíèå ïàðàìåòðàìè áëîêà /
Remote
control of unit parameters
Ïîääåðæêà äî 5 àêêàóíòîâ ñ íàñòðîéêàìè àäìèíèñòðàòîðà / Support for up to 5 accounts with administrator
settings
Óäàëåííîå óïðàâëåíèå ðîçåòêàìè (âêëþ÷åíèå, âûêëþ÷åíèå, ïåðåçàãðóçêà) /
Remote
control
of
sockets
(
turn
on
,
turn
off
,
reboot
)
Ïîëüçîâàòåëüñêîå ïîñëåäîâàòåëüíîå îòêëþ÷åíèå ñ çàäåðæêîé èëè âûáîð çàäåðæêè îòêëþ÷åíèÿ ïî
æåëàíèþ ïîëüçîâàòåëÿ /
User
-
defined
series
tripping
with
delay
or
selection
of
off
-
delay
at
the
wish
of
user
Çàïîìèíàíèå ïîñëåäíåãî âêëþ÷åíèÿ / Memory retention of last switching on
Ïîëüçîâàòåëüñêàÿ óñòàíîâêà ïîðîãà îãðàíè÷åíèÿ ïî òîêó, íàïðÿæåíèþ, âõîäíîìó òîêó / Custom setting of
the current, voltage, output current limiting threshold
Óäàëåííûé
ìîíèòîðèíã
ïàðàìåòðîâ
áëîêà
/ Remote
monitoring of unit parameters
Òîê, À / Ñ
urrent
, À
Íàïðÿæåíèå, Â /
Voltage
,
V
Ìîùíîñòü, êÂò / Ð
ower
,
kW
Êîýôôèöèåíò ìîùíîñòè,
PF
/
Power
factor
,
PF
Îêðóæàþùàÿ
ñðåäà
â
ñòîéêå
(
øêàôó
) –
âëàæíîñòü
/
òåìïåðàòóðà
(
ïðè
ïîäêëþ÷åíèè
âíåøíåãî
äàò÷èêà
òåìïåðàòóðû
/
âëàæíîñòè
) /
Å
nvironment in the rack (cabinet)
–
humidity/temperature (when connecting an
external temperature / humidity sensor)
Ïîëîæåíèÿ
ãëàâíûõ
êîíòàêòîâ
àâòîìàòè÷åñêîãî
âûêëþ÷àòåëÿ
(
âêëþ÷åí
/
âûêëþ÷åí
) /
Ð
osition of the main
contacts of the circuit breaker (on/off)
Êîëè÷åñòâî ïîòðåáëÿåìîé ýíåðãèè, êÂò·÷ / Ð
ower
requirement
,
kW
·
h
Íàïðÿæåíèå
,
òîê
è
êîýôôèöèåíò
ìîùíîñòè
êàæäîé
ðîçåòêè
/ Voltage, current and power factor of each
socket
Óäàëåííûé äîñòóï / Remote access
Óäàëåííûé äîñòóï ÷åðåç TCP/IP è âñòðîåííûé 10/100 Ethernet ïîðò / Remote access via TCP / IP and built-
in 10/100 Ethernet port
Ïîääåðæêà SNPM V1, V2 è V3 / SNPM V1, V2 and V3 support
Ïîääåðæêà Modbus RTU / Modbus RTU support
Ïîääåðæêà ïðîòîêîëà ñåòåâîé ñâÿçè, âêëþ÷àÿ TCP/IP, TELNET, SSL, SMTP, DHCP, SNTP è DNS / Network
communication protocol support, including TCP/IP, TELNET, SSL, SMTP, DHCP, SNTP