Professional Series Thermal Imagers
Menus
23
To use the distance measurement feature:
1. Turn on the distance feature and select the units to show on the display.
2. Point the Imager at the target.
3. Pull and hold the
Secondary Trigger
.
*
shows at the top of the display.
4. Position the red laser dot on the target.
5. Release the
Secondary Trigger
.
The distance measurement shows on the bottom of the display. The measurement shows as “- - - -” when
the Imager cannot take a measurement. If this is the case, use a tripod or steady the Imager and retake the
measurement. If there is excessive laser movement, an error message shows on the display due to an out of
range distance.
Camera Menu
Table
lists the options in the Camera menu.
Table 12. Camera Menu
Option Menu
Option
Description
LaserSharp
Autofocus
On
Turns on LaserSharp Autofocus to automatically focus on a target.
See
Off
Turns off LaserSharp Autofocus to use the Advanced manual focus.
See
Backlight
<options>
Select to set the brightness level of the display.
Torch
--
Turns on/off the built in flashlight.
Video
Video/Audio
Select to record video and audio when
Record Video
is selected.
Video ONLY
Select to record video only when
Record Video
is selected.
Record Video
Select to start recording a video. See
.
www.
.com
information@itm.com
1.800.561.8187