Professional Series Thermal Imagers
Radio Frequency Data
45
Keep the Imager attached to the charger until the battery condition icon shows a full charge. If you remove the
Imager from the charger before a full charge shows, it can have a reduced run-time.
Note
When the battery is connected to ac power or the unit is in video mode, the Sleep Mode/Auto Off feature
is disabled automatically.
Optional 12 V Vehicle Charger
1. Connect the 12 V adapter into the 12 V accessory socket of the vehicle.
2. Connect the output to the ac power socket of the Imager.
3. Charge until the indicator shows
full
on the screen.
4. Disconnect the 12 V adapter and Imager when battery is fully charged.
W
Caution
To prevent damage to the Imager, remove it from the dc car charger before you start or jump
start the vehicle.
•
Always operate in the specified temperature range.
•
Do not store the batteries in extreme cold environments.
•
Do not attempt to charge the batteries in extreme cold environments.
~
W
Caution
Do not incinerate the Product and/or battery.
Radio Frequency Data
See Table
for instructions on how to access digital copies of the Certificate IDs on the Imager.
General Specifications
Ti300 PRO
Ti400 PRO
Ti401 PRO
Ti450 PRO
Ti450 SF6
Ti480 PRO
Temperature
Operating
-10
°
C to 50
°
C (14
°
F to 122
°
F)
Storage
-20
°
C to 50
°
C (-4
°
F to 122
°
F) without batteries
Relative Humidity
10 % to 95 % non-condensing
Altitude
Operating
2000 m
Storage
12 000 m
Display
8.9 cm (3.5 in) touchscreen diagonal landscape color VGA LCD with backlight
www.
.com
information@itm.com
1.800.561.8187