Enclosure 6N Pressure Switches
Page 3
CHAPTER
2
INSTALLATION
Installation of these Neo-Dyn
®
Enclosure 6N pressure switches is straightforward.
However, they must be installed by a qualified electrician, in compliance with all local
and national electrical codes.
WARNING
Electrical hazard
WARNING
Do not make electrical connections while power is on.
WARNING
Always check for multiple circuits.
WARNING
Always make sure grounding is adequate.
WARNING
Do not remove switch while under pressure.
MOUNTING
The pressure switch can be mounted directly to the process connection if there is no
significant vibration and the fluid lines are capable of supporting the weight; in addition,
Models 125P, 132P, 225P, and 232P can also be attached to a flat surface, such as a wall
or panel, using .190 in. diameter (no. 10) or M5 fasteners through the mounting holes that
are spaced 1.125 in. (28.6 mm) apart. The fastener length should include 1.50 inch (38.1
mm) above the mounting surface.