d) WATER OF HIGH PURITY:
Production can decrease up to a 10%.
Connections to the Water Network
Use a flexible pipe with the two filter joints supplied with the machine. Pressure
should be established between 1 and 5 Kg/cm
2
If pressures overpass such values, install the necessary corrective devices.
Leave free the needed length to extract the machine up to the end of the guides.
The rest can be flanged and gathered at a side to avoid that when storing the
machine it can touch the water pump and stop it or make noise.
Connection to drainage
The drainage must be in the position established in the drawing. In the left part of
the housing and below the inferior level of the machine. In this way the flexible
pipes have the enough path to allow the extraction of the machine.
it is convenient that the drainage pipe has an entry with an interior diameter of 50
mm to introduce the two drainage hoses of the machine.
Fix the pipes with the flanges that were provided. Thus, we ensure that when
taking out and storing the machine, the pipes do not come out.
Electrical connection:
The machine is provided with a 1.5 m (4.92 feet) cable with a schucko jack. In case
the supply cable is damaged, it should be replaced by a cable or a special
assembly to be furnished by the manufacturer or post-sale service.
Safeguard the base of the jack.
It is convenient to install a switch that allows the total disconnection of the machine
without taking it out.
IT IS MANDATORY TO GROUND THE EQUIPMENT
To avoid possible discharges on individuals or damages to the equipment, the
machine should be grounded pursuant local and/or national regulations as the
case may be.