26) The ice cubes are made,
but
they
they
aren’t
removed.
A) Water inlet filters are dirty.
A) Clean filters.
27)
B) Low water pressure.
B) Increase
pressure.
(Sometimes,
the
problem is solved by
removing
the
flowmeter from the
water inlet valve).
28)
C) The fan or condensation pressure switch is
too low or damaged.
C) Regulate or change.
31)
F) Room or water temperature below 7º C.
F) Increase
removal
time.
32)
G) Damaged programmer.
G) Check and eventually
change.
33)
H) Manufacture time too long. The ice cubes
have burrs out of the mold.
H) Regulate,
reducing
manufacturing time.
34)
I) Faulty or wrongly connected hot gas valve.
I) Check and eventually
change.
35) Low ice production.
A) Dirty condenser, air flow blocked or hot air is
received from another device.
A) Clean
condenser,
release air flow or
change the machine
location.
37)
C) Hot gas valve is faulty, it always lets some
hot gas (the tube temperature indicates so).
C) Replace the hot gas
valve.
38)
D) The pressure switches of the fan or the
condensation water inlet valve are faulty or
were regulated too low.
D) Regulate or change.
39)
E) Excessive or short coolant load.
E) Adjust the load.
40)
F) The water inlet valve doesn’t close (it leaks).
F) Check and change if
necessary.
41)
G) Inefficient compressor.
G) Change
the