MR400 MAINTENANCE
2.
Remove the expulsion grille for fallen ice. (Clean it just like the curtain.)
3.
Disassemble the injectors and clean them.
4.
Disassemble and clean the main filter of the water pump. (It is pressure-assembled.)
5.
Install filter, injectors and collectors.
CAUTION: IT IS VERY IMPORTANT WHEN YOU RE-INSTALL THE COLLECTOR THAT
THE INJECTORS ARE PUT BACK IN THE SAME POSITION.
6.
6.
Assemble the ice cube expulsion grille.
(CAUTION: IT MUST BE FIRMLY SECURED TO THE SIDE ANCHORS).
7.
Clean the curtain with phosphoric acid and rinse.
8.
Install the curtain. Make sure that all the slats move freely.
9.
Turn the machine on and discard the first batch of ice.
6.
MAINTENANCE TABLE:
MAINTENANCE
Dusty ambient
Normal ambient
Air condenser cleaning
6 months
12 months
MAINTENANCE
Hard water (over 400ppm)
Soft water (less than 400 ppm)
Water filter changing
6 months
12 months
Hydraulic circuit cleaning
6 months
12 months
7.
CONTROL OF WATER LEAKS:
Whenever you open up the machine, check all the water connections, the condition of the
washers and hoses to avoid leaks and to prevent breakages and flooding