http://www.itvsystems.com.ua
Integrated Technical Vision Ltd
13
Terminal assignment
Connectors
-
X5 - Not Used - for future use
-
X4 - RS-232 communication port
Jumpers and LED
-
RST - Reset jumper
-
S2 - Address of the control panel
-
S3, S4, S6 Jumpers for RS-485 load selection
-
BAT - Real-time clock’ power switch.
-
LED - Live function indicator (Yellow)
Set jumper BAT during panel installation and withdraw it for storage and transportation
to avoid lithium battery discharge.
Control Panel Operation
Control panels are supplied unprogrammed. In this state reader's LEDs do not light.
Yellow LED situated on PCB blinks 5 times per second. Panel does not respond to
cards passing and inputs opening and closing. The panel should be downloaded to
start the operation with DC Configurator or Golden Gate program.
Yellow LED starts to blink one time per second and switches to the main mode
automatically after successful settings’ downloading.
The panel can be turned to unloaded status only with command from PC, see
programming instruction.
The panel can control two independent access points. Each access point may be in
one of the four modes: main mode, alarm, blocked or free pass. Free pass mode
has the highest priority, as panel switches to this mode in case of fire, then
blocked, alarm and main modes follow.
Main Mode
Panel grants or denies access to cardholders in this mode. In main mode reader’s
LEDs blink red.
Access with ID
To access the premises cardholder passes RF ID to reader. If it is valid, panel
grants access, unlocks the door and switches on green LED of the reader.
Access with ID and PIN
To access the premises cardholder passes RF ID to the reader. Panel checks up
the necessity of PIN entry, and, if it is necessary, reader's LED blinks yellow,
which means PIN is awaited. After valid PIN entry door is unlocked. Reader's
LED lights green.
RTE button
To exit from the premises with single-sided door, user has to depress (press and
release) Request To Exit button. Reader's LED lights green.
Control Panel Operation
Summary of Contents for NDC-F18
Page 2: ...2 Integrated Technical Vision http www itvsystems com ua ...
Page 4: ...4 Integrated Technical Vision http www itvsystems com ua ...
Page 23: ...http www itvsystems com ua Integrated Technical Vision Ltd 23 ...
Page 24: ...24 Integrated Technical Vision http www itvsystems com ua 060504 ...