SERVICE MANUAL SPIKA SERIES
37
8. USER TROUBLESHOOTING GUIDE
8.1. Under counter models
PROBLEM
PROBABLE CAUSE
SOLUTION
None of the electrical parts
work.
The machine is unplugged.
Plug in the machine and verify socket power
Bin thermostat open. Ice touching
bin tube.
Remove ice from the bin.
Bin thermostat open. No ice
touching bin tube.
Adjust thermostat (electric box under top cover)
All the electrical parts work
but not compressor. (water
doesn´t freeze)
Compressor switch is in the
“
WASH
” position (0).
Switch to “
ICE
” position (1).
No water in tray
Not incoming water
Check water supply
Inlet strain at water valve blocked
Check and clean
Bin full and ice touching
thermostat tube, but machine
doesn´t stop
Bin thermostat doesn´t open (only
operates at harvest time)
Adjust thermostat (electric box under top cover)
Ice slab empty or too thick
Desadjusted cycle time
Adjust thermostat (electric box under top cover)
Difficult to release ice slab at
harvest
Unit bad leveled (tilted to back)
Level; down front
Not enough harvest time
Add more pins to cam timer wheels (as label
indications)
Not uniform flow pattern at
evaporator
Dirty or scaled distributor
Perform descaling procedure.
Remove and clean distributor (pull from two clips
at distributor sides)
Unit
run
and
stops
alternatively itself
Safety pressure switch opens
Clean air condenser (behind front grid)
For further problems call aftersales service
Summary of Contents for SPIKA MS 1000
Page 39: ...SERVICE MANUAL SPIKA SERIES 39 9 WIRING DIAGRAMS 9 1 SPIKA NG under counter models ...
Page 40: ...SERVICE MANUAL SPIKA SERIES 40 9 2 SPIKA MS 700 ...
Page 41: ...SERVICE MANUAL SPIKA SERIES 41 9 3 SPIKA MS 500 AND SPIKA MS 1000 A W ONE PHASE ...
Page 42: ...SERVICE MANUAL SPIKA SERIES 42 9 4 SPIKA MS 1000 THREE PHASES ...