2.6. Drain connection
Drainage should be located lower to the machine level, at 5.
9” (150mm) minimum.
It is convenient that the drain hose is 1,18” (30mm) inside diameter and with a minimum
gradient of
0.36’’ / ft (3cm/metre), see figure.
2.7. Electrical connection
It is mandatory to ground the equipment. To avoid possible electric shock on individuals or
damages to the equipment, the machine should be grounded pursuant local and/or national
regulations as the case may be.
The manufacturer shall be held harmless in case of damages arising due to the lack of the
ground installation.
In case the supply cable is damaged, it should be replaced by a cable of special assembly to be
furnished by the manufacturer or after-sales service. Such replacement should be performed by
qualified technical service only.
The machine should be places in such a way as to allow a minimum space between the back
and the wall to allow an easy access and without risks to the cable plug.
Safeguard the socket. It is convenient to install adequate switches and fuses.
Voltage is indicated in the nameplate and on the technical specifications section of this manual.
Variation on voltage above the 10% stated on the nameplate could result on damages or
prevent the machine start-up.
Correct
I
ncorrect
Incorrect
Summary of Contents for SPIKA MS 1000
Page 39: ...SERVICE MANUAL SPIKA SERIES 39 9 WIRING DIAGRAMS 9 1 SPIKA NG under counter models ...
Page 40: ...SERVICE MANUAL SPIKA SERIES 40 9 2 SPIKA MS 700 ...
Page 41: ...SERVICE MANUAL SPIKA SERIES 41 9 3 SPIKA MS 500 AND SPIKA MS 1000 A W ONE PHASE ...
Page 42: ...SERVICE MANUAL SPIKA SERIES 42 9 4 SPIKA MS 1000 THREE PHASES ...