SERVICE MANUAL
SPIKA SERIES
39
PROBLEM
PROBABLE CAUSE
SOLUTION
Ice cycle timeout
No frozen evaporator
Check compressor and refrigeration system
NTC probe faulty contact
Check probe fitting and insulation
Harvest cycle timeout
Ice slab not released
Faulty hot gas valve
Bad leveled unit. check
water time too short. Increase
No ice on evaporator
No water in tray.
- check water supply
- check water valve and strainer
- check water leaks
Faulty pump. Verify
Faulty curtain sensor
Check sensor and wiring
For further problems call aftersales service
8.2.- MODULAR MODELS
PROBLEM
PROBABLE CAUSE
SOLUTION
None of the electrical parts
work.
The machine is unplugged.
Plug in the machine and verify socket power
Rear switch OFF
Switch ON
Front switch position 0
Move to ICE (behind front panel)
All the electrical parts work but
not compressor. (water doesn´t
freeze)
Front switch position WASH.
Move to ICE (behind front panel)
No water in tray
Not incoming water
Check water supply
Inlet strain at water valve blocked
Check and clean
Not enoug water to end cycle
Water level probe too low
Move up (steel rod beside pump)
Defective drain valve (check drain
leak during ice stage)
Disassemble and clean
Shield splash leaks
Check shield position
Water overflows tray
Level probe too high or scaled
Adjust / clean
Ice slab empty or too thick
Desadjusted/scaled
thickness
probe
Adjust / clean
Difficult to release ice slab at
harvest
Unit bad leveled (tilted to back)
Level; down front