W i r e l e s s   a c c e s s   c o n t r o l   p a n e l   w i t h   b u i l t   i n   r e a d e r  

 

 
 
 

Wireless  

access control panel 

U-Prox IP560 

Instruction manual

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

   

 

 

 

 

Summary of Contents for U-Prox IP560

Page 1: ...1 000 W i r e l e s s a c c e s s c o n t r o l p a n e l w i t h b u i l t i n r e a d e r Wireless access control panel U Prox IP560 Instruction manual ...

Page 2: ...Order of installation adjustment of external devices and panel configuration are described in Working with the device section Technical support To get warranty and technical support you can apply to authorized service centers situated on the territory of countries enlisted in the warranty card Warranty and technical support are performed on the territory of the country where the customer applied f...

Page 3: ...Free pass mode 33 Blocking mode 33 RF ID properties 34 Variants of Use and modes of output 34 The communicator 34 Server addresses automatic configuration for U Prox IC L 37 How to work with the device 40 Installation recommendations 40 Installing Panel 40 Connecting an external reader 40 Loops connection 41 Request to Exit button RTE 41 Door Contact 42 Actuators 42 Electric locks 42 Bells 43 Alar...

Page 4: ...the network To add it to access control network U Prox IC L control panel used U Prox IC L panel communicates with U Prox IP 560 via ISM band radio and via Ethernet wired computer network with access control system server To extend the range of wireless system U Prox HE and U Prox HW repeaters are used communicating with U Prox IC L over Ethernet wired computer network or Wi Fi wireless computer n...

Page 5: ...ontrol system server via computer network Antipassback Real time clock Nonvolatile memory Standalone operation mode 255 user ID s including 1 master code 1 engineer code 4096 events Day and Night modes In system operation mode 3000 user ID s 6000 events 255 time zones 255 week schedules 255 holidays Dimensions 119 4х65 4х24 mm Weight 0 2 kG Description and operation Panel The look of the access co...

Page 6: ...open СM1 Common NC2 Normally closed Relay 2 contacts NO2 Normally open СM2 Common SAB TAMPER Tamper Enclosure and removal tamper RED Reader power 12V External reader connection GND GND D1 Data 1 D0 Data 0 EIN Programmable input Inputs GND GND DC Door contact RTE Request to Exit button 3 1 1 Panel cover 2 Panel cover and bottom board connection cable 3 Nuts for fixing screw Bottom may turn on 180 g...

Page 7: ...ks for new code entry Bluetooth indication Operation mode Bluetooth indication Normal mode No sound no indication Connected No sound Blue light continuously Programming allowed No sound Blue light blinks fast Connected no correct data received Short beeps Blue light blinks once per second In 5 seconds connection reset Panel operation The panels supplied unloaded with factory settings below in docu...

Page 8: ...r code User codes their names and parameters Relay operation modes and entry exit duration for each user personally Alarm output duration Keypad blocking duration User codes This codes allow to Drive relays Switch panel into the night operation mode and vice versa Administrator adjusts code category and options for each code individually Code category defines the access mode Code options define nu...

Page 9: ...rresponding parameter for all codes with durations set to default Example The value of 255 is set automatically to relay duration for each newly created code which means that the default value used factory setting 3 sec If somebody sets relay duration value 255 to several codes it will mean that codes have default relay duration It is enough to change default relay duration to change the relay dur...

Page 10: ...sible to switch panel into the night mode but will not be any way to return to day mode Panel performs all actions programmed for normal user code and activates Alarm output for programmed time on duress code entry Alarm output activates after the code entry immediately If there were no any keypad activity panel will return to normal mode in 40 seconds Panel programming in standalone mode Download...

Page 11: ... displayed at scan Enter engineer s code on the keypad panel will allow connection for programming for 40 seconds Access reject message displayed on attempt to connect without authorization Select panel from the device list and press Connect button Application will read out panel settings ...

Page 12: ...12 http u prox com The main menu will activate after the settings readout Advanced options displayed after More button pressed The menu item Save To Device became active after settings adjustment Select Save To Device to save changes ...

Page 13: ...sion Ltd http u prox com 13 Press Disconnect button to break connection with panel Attention Disconnection without writing settings will cause changes loss Settings menu item contains main panel settings Device settings group ...

Page 14: ...ing Firmware and Bluetooth firmware firmware version and upgrade Available issue keys the number of free cells in memory for identifiers Master code code 0 change Engineer s code code 1 change New code accepted if it is not equal to any other code in system including duress codes ...

Page 15: ...x com 15 Code match keypad blocking duration at code match attempt Allowable values 5 seconds to 4 minutes or code match function disable Alarm alarm output activity duration Allowed values 0 to 240 seconds or deactivation with engineer s code ...

Page 16: ...ration modes alarm Button press activates alarm output day and night access RTE active always work time access only RTE active when panel is in day mode only day and night modes switch RTE press alters day and night panel modes unused RTE is disabled Action actuators actions settings after RTE button press ...

Page 17: ...7 Door time delay duration setting after RTE button press Front button built in RTE button enabling and disabling see fig 1 Access settings group Access Door time Sets default value for Entry exit duration Allowable values 0 240 seconds or door opened ...

Page 18: ...F ID type selection ASK only FSK only or ASK and FSK simultaneously Attention ASK and FSK modulation is ON by default Default Relays time settings of default duration of Relay 1 and Relay 2 activation Allowable values 0 254 seconds Zero value used for relay trigger mode ...

Page 19: ...ime set and in night mode outside it Manual switch by passing ID with appropriate option between Night and Day modes possible only if automatic change mode is Off Panel starts to beep every second in one minute before automatic switch into the Night mode and beeps 2 times every second in 20 seconds before switch Press Back to exit Settings menu ...

Page 20: ...entry contains Access type day white background day and night orange background or without access white background Code name or numeric value of the code if name was not set Type of ID keypad code RF ID or mobile ID To remove code from the list swipe it from right to left Element marks as removed To restore it press Cancel ...

Page 21: ...ey This action adds RF ID to the list of ID s with default settings To enroll new code manually press Add button and then Code enter code its name and code parameters Press Apply to save changes To enroll new mobile ID press Add button and then Mobile ID by e mail Enter the visitor s email address and select the e mail program will be formed invitation letter Click Send You can send invitation fro...

Page 22: ...ion or in the browser The U Prox ID application will automatically start asking you to confirm the visit Click the button and select the mail program Send e mail back to the person who sent you Invitation Installer will receive e mail containing a link to activate access Click on the link depending on the settings of smartfone you will be offered to open the link in the ...

Page 23: ... browser The U Prox Config application will automatically start After downloading the confirmations connect to the controller and process the confirmations Go to the menu item Access and select Approved invites A confirmation list will open Click Mobile IDs will move to the general list ...

Page 24: ...Integrated Technical Vision Ltd 24 http u prox com To change settings for code select it in the list nap it The settings window will open Change card name and settings Press Apply to save the changes ...

Page 25: ...Integrated Technical Vision Ltd http u prox com 25 It is possible to set personally for each identifier access type Door open duration after the grant of access ...

Page 26: ...Integrated Technical Vision Ltd 26 http u prox com action type after the ID pass Relay activation duration if relay selected in item above Press Apply button to save changes ...

Page 27: ... list click on it and hold until it is highlighted in color Select other identifiers Next click the settings window will open Change cards settings Press Apply to save the changes Press Back button to exit Access menu item To view the event log use Log menu item Press button to export log Press Back button to exit Log menu item ...

Page 28: ...his item selected Firmware upgrade process will start after desired file selection Attention All files with firmware must store in Download folder in main mobile device memory Panel settings save and restore available from Save and Restore menu items of the advanced options All settings saved into the file with eep extension in Download folder in main memory of the mobile device ...

Page 29: ... menu item selection Select one of them to restore settings into the panel Mobile ID Download and install U Prox Mobile ID application Run U Prox ID application Mobile devices with Android 5 0 OS and higher Apple 8 0 IOS and higher supported Device must have Bluetooth 4 0 and higher with BLE Bluetooth Low Energy support ...

Page 30: ...lication If Bluetooth is not activated on your device application will request for activation press OK Attention The location services must be ON in Android 6 0 and higher for Smart Bluetooth operation Attention Button in application will be inactive until any invitation for access is received and confirmed ...

Page 31: ...Integrated Technical Vision Ltd http u prox com 31 Panel will grant access if code where enrolled in it and have correct access rights Panel and application indication will change ...

Page 32: ... Exit button Door opens i e actuator powered after press with subsequent depress of the Request to Exit button reader LED lights Green Access deny on RF ID pass Access may be denied to RF ID holder for reasons as follows LED lights Red panel was not downloaded LED not lights RF ID was not enrolled in the panel for 1 second sounds the buzzer and LED lights Red RF ID term of use expired for 1 second...

Page 33: ...e All time long while panel is in Free Pass mode it keeps lock opened fixes RF ID passes and code entries saving in the event memory and sending to the system server access granted events independently on the antipassback access rights e t c settings and state This information used for supervision of personnel presence in premises in case of emergency Blocking mode Panel may block access point for...

Page 34: ...y service flag passed to the reader of the blocked door Antipassback disabled Antipassback disabled flag gives right to move freely in any direction through the door with antipassback to the user with this card Panel grants access to the card with this flag based on card access rights independently on card position previous door pass direction VIP User with card with VIP flag can open any doo at a...

Page 35: ...ignals Periodic test signals used for communications supervision Test messages transmitted every two 2 seconds The backward commands from access control system received with acknowledgments to event messages or periodic test signals Panel provides encryption protection of the data and commands with 256 bit key and protection against panel substitution due the unique serial number supervision Both ...

Page 36: ...ode i e make decision about the access using data uploaded beforehand U Prox IC L control panel routes data from the allowed U Prox IP560 wireless panels via U Prox HE and U Prox HW repeaters The U Prox IP access control system server U Prox IC L U Prox HE and U Prox HW communicate each other via the computer network The U Prox IC L U Prox HE and U Prox HW communicate to the U Prox IP560 wireless ...

Page 37: ...ontrol panel connection 2 U Prox HE repeater s connection 3 U Prox IP560 wireless panels connection Fig 6 Wireless lock system deployment The algorithms for operation on each step described below Server addresses automatic configuration for U Prox IC L 1 Panel checks for DHCP mode ON panel address 0 0 0 0 or static IP 2 If DHCP mode is ON the dynamic IP address obtain routine will start 3 The pane...

Page 38: ...r sends data packages announcing U Prox IC L panel about itself as a new device in the local network b The system will warn operator after the receiving of the data package from the new repeater through the U Prox IC L panel Than operator must add repeater to the system database DB c Operator has to upload U Prox IC L panel after repeater recorded into the DB d After the U Prox IC L panel uploaded...

Page 39: ...l b Data packages are received with U Prox HE repeaters and send to the U Prox IC L control panel c U Prox IC L panel sends event message to the access control system server d Access control system server warns operator about the new panel Operator must add panel to the system database e Operator must upload U Prox IC L control panel after the U Prox IP560 panel added to the DB f Operator must upl...

Page 40: ... cable close and fix it with screw 9 Turn ON desired standalone or in system mode 10 If panel is in standalone mode adjust and download settings with mobile application 11 If panel is in in system mode connect it with system server and adjust it from system server 12 Panel is ready for work Installing Panel Panel should be installed on the wall next to the door for users may easily pass card to it...

Page 41: ...RTE Door Contact RTE Free pass A B A B Blocking A B A B Sensors monitoring Request to Exit button RTE RTE is used for exit through single sided door In this case access point opens when you press and release RTE Use this input type for remote door opening button connection also For example to open the door manually by the secretary or security guard The example of normally open contact RTE button ...

Page 42: ...uts panel controls electric locks or latches operation of the barrier or turns on any optional hardware Relays normally closed and normally open contacts The relay contacts rating is 3A 24 V Electric locks Normally closed and normally open relay contacts are programmable for a wide range 0 255 sec of lock operation time Panel controls electric lock or latch barrier operation turnstile or turns on ...

Page 43: ...lay outputs as outputs of locks at panel programming for proper operation Bells Bell see Fig 14 is inductive load for power source use protection diode connecting it to direct current source see warning about inductive load above Fig 14 Bell connection Consult your supplier before connection of actuators magnetic starters turnstiles barriers etc Alarm output Alarm output is open collector ALM shor...

Page 44: ...der type 26 or 42 bits d Panel inputs adjustment input type and access point for example Door contact access point A and B or free pass access point B e Panel outputs adjustment output type lock bell etc operation mode access point activity duration if applicable to type controlling input 3 Create list of users with ACS containing IDs with options schedules of access rules for exact access points ...

Page 45: ...e in system mode To switch into the in system mode proceed 1 Depower panel 2 Remove the top cover of panel leaving connected cable running to the bottom board 3 Short ALM and RTE terminals 4 Power up panel 5 Wait for tree short long beeps signaling the successful panel switch into the standalone mode 6 Depower panel and remove short from ALM and RTE terminals Factory settings Mode standalone Maste...

Page 46: ...cal unit of ACS controlling passage through the access point in one direction It includes reader access control panel or part of access control panel actuator So tourniquet with double sided control has two passageways and the door having single sided reader only one passageway Access point which consists of two passageways is called double sided and the point of access which consists of one direc...

Page 47: ...atching Code matching is considered when invalid code or RF ID is entered several times successively Valid code entering clears the counter This function switching On and number of code entrances are subjects of programming Schedules Date and time of valid access are indicated when setting user access rights Control panel stores up to 250 time zones 250 week schedules can be combined from these ti...

Page 48: ...if lock closed when powered used You may use Relay 1 contacts for optional devices control Panel settings example Alarm output duration 10 seconds Keypad blocking time 40 seconds Engineer s code 1234 Master code 5678 User code 1 2 2 2 2 code type 4 active day user can t change own code controls relay 2 Entry exit duration 30 seconds User code 2 3 3 3 3 code type 4 active day user can t change own ...