Integrated Technical Vision Ltd.
47
function is on, control panel tracks an RF ID position
– inside or outside the premises.
On any attempt to pass in the same direction twice the panel denies access and stores
“Access Denied, Antipassback” event into the Log.
Antipassback function can be set on only in case of the double-sided door control.
Door time
If door sensor is open, corresponding access point goes into alarm. Alarm is not
invoked, if contact is opened during Door Time interval. This interval starts when
access is granted and lasts for the programmed time or terminates on opening and
subsequent closing of door contact.
Code matching attempt
Control panels can activate alarm on attempt of a code (or RF ID) matching. Code
matching is considered when invalid code (or RF ID) is entered several times
successively. Valid code entering clears the counter. This function switching On and
number of code entrances are subjects of programming.
Schedules
Date and time of valid access are indicated when setting user access rights. Control
panel stores up to 250 time zones.
250 week schedules can be combined from these time zones.
Moreover, control panel can store up to 250 holidays, which happen once a year.
Time zones
Time zones are a part of schedule. This is a way to organize a range of days and times
and associate it with access levels.
Time zones are utilized by the application to validate, authorize, or perform various
functions based on schedules.
Downloading
Control panel is to be downloaded after all parameters are set
– modes of inputs,
outputs, access rights and others. During downloading parameters are rewritten into
access control panel.