Chapter 5
Maintenance and Repair Notes
ITW Dynatec
Dyna BFS Applicator, Rev.9.16
Page 31
5.3 Purging the Filter Element
ADVICE
Heed all security advices given in chapter 5.1.
MAINTENANCE
For preventive maintenance and avoidance of malfunctioning, we recommend replacing
the filter element after ca. 200 operational hours.
1. Stop adhesive supply/ all motors.
2. Place a heat-resistant catchment
container/underlay under the Applicator. Hot
adhesive may come out.
3. Switch on adhesive supply.
4. Screw out the screw plug using a SW5
hexagon socket screw key until the stop screw
is reached. When unscrewing the screw plug,
adhesive will come out from the outlet on the
underside of the supply block.
5. Let adhesive flows out until the the emerging
adhesive is uncontaminated.
6.
Screw the
locking screw again, until it stops.
After finishing the maintenance or repair works:
Remove all materials and tools used during the
repair or maintenance from the workspace of
the unit.
Continue production.
Stop screw
Screw plug