Chapter 3
Installation
ITW Dynatec
Dyna BFS Applicator, Rev.9.16
Page 19
Chapter 3
Installation
CAUTION
•
Before setting up, please read this documentation carefully.
•
Pay attention to all the installation and connecting advices.
•
Heed all safety instructions mentioned in Chapter 1.
3.1 Conditions for set-up and mounting
Place requirement
Install the Applicator in the machine so that the operator is able to work on it from all
sides, for e.g. for adjusting, preparing, maintaining, repairing, cleaning, etc. See drawing
in Chapter 2.
Electrical connection
•
Provide necessary electrical connection. See electrical schematics.
•
The unit has to be connected according to the schematics. Heed the regulations of the
VDE or local power supply organization in all cases!
•
Never connect or disconnect plug-and-socket connections under load!
Pneumatic connection
Provide necessary pneumatic connection:
•
The required air pressure is 6 bar.
•
Connect a compressed-air supply hose of DN8 at least to the Spray Applicator.
CAUTION: In any case the air has to be clean and dry! See advice in Chapter
“Quality of compressed air”.
•
Please heed that units with high air demand may not be used at the same time with
the same air supply.
ADVICES
•
Check all screw connections at the unit and retighten if necessary.
•
Lay the cables and heated hoses so that no risk or least possible risk of stumbling
occurs.