INSTALLATION CODES AND STANDARDS 

The Stockpot Range must be installed in accordance with: 

In the United States of America: 

1.  State and local codes. 

2. National Fuel Gas Code, ANSI-Z223.1/NFPA #54 (latest edition). This shall include but 

not be limited to: NFPA #54 Section 10.3.5.2 for Venting. Copies may be obtained 
from The American Gas Association Accredited Standards Committee Z223,  @ 400 
N. Capital St. NW, Washington, DC 20001 or the Secretary Standards Council, NFPA, 
1 Batterymarch Park Quincy, MA 02169-7471  

 

NOTE: In the Commonwealth of Massachusetts 

 

All gas appliances vented through a ventilation hood or exhaust system equipped with 
a damper or with a power means of exhaust shall comply with 248 CMR.  

3.  NFPA Standard # 96 

Vapor Removal from Cooking Equipment

, latest edition, available 

from the National Fire Protection Association, Batterymarch Park, Quincy, MA 02269. 

In Canada: 

1. Local codes. 

2.  CAN/CSA-B149.1 Natural Gas Installation (latest edition)   

3.  CAN/CSA-B149.2 Propane Installation Code (latest edition), available from the 

Canadian Gas Association, 178 Rexdale Blvd., Etobicoke, Ontario, Canada M9W 
1R3 

 

GAS PRESSURE REGULATOR INSTALLATION 

Gas regulator pressure is preset at 5” Water Column (W.C.) for natural gas, and 10” W.C. 
for propane gas. Minor adjustments may be required based on site specific gas pressure. 

Install the regulator as close to the stockpot on the gas supply line as possible. Make 
sure that the arrow on the underside of the regulator is oriented in the direction of gas 
flow to the stockpot (Fig. 2) and the regulator is positioned with the vent plug and 
adjustment screw upright (Fig. 3). 

 

Fig. 2 

 

Fig. 3 

The minimum supply pressure (upstream of the regulator) should be 7-9” W.C. for natural 
gas and 11-12” W.C. for propane gas. At no time should the hotplate be connected to 
supply pressure greater than ½ psig (3.45 kPa) or 14” W.C. 

 

Summary of Contents for ML-052822

Page 1: ...TAIN THIS MANUAL FOR FUTURE USE FORM F 36951 04 07 INSTALLATION OPERATION MANUAL FOR Stockpot Range MODELS MLS VSP100 ML 052822 VSP200 ML 052823 VSP200F ML 769292 www vulcanhart com MODELS MLS WSPR1 ML 760600 WSPR2 ML 760601 WSPR2F ML 769292 www wolfrange com VSP100 WSPR2F ...

Page 2: ...PORTANT IN THE EVENT A GAS ODOR IS DETECTED SHUT DOWN UNITS AT MAIN SHUTOFF VALVE AND CONTACT THE LOCAL GAS COMPANY OR GAS SUPPLIER FOR SERVICE FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE WARNING IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE INJURY OR DEATH READ THE I...

Page 3: ...the clearance dimensions see below agree with the specifications on the rating plate which is located at the back of the stockpot LOCATION The installation location must be kept free and clear of combustibles Do not obstruct the flow of combustion and ventilation air DO NOT install the stockpot adjacent to open burners or fryers Sufficient air should be allowed to enter the room to compensate for ...

Page 4: ...tion Association Batterymarch Park Quincy MA 02269 In Canada 1 Local codes 2 CAN CSA B149 1 Natural Gas Installation latest edition 3 CAN CSA B149 2 Propane Installation Code latest edition available from the Canadian Gas Association 178 Rexdale Blvd Etobicoke Ontario Canada M9W 1R3 GAS PRESSURE REGULATOR INSTALLATION Gas regulator pressure is preset at 5 Water Column W C for natural gas and 10 W ...

Page 5: ... A pressure regulator is supplied and must be installed outside of the broiler when making the gas supply connection Standard orifices are set for 5 WC Water Column for Natural Gas 10 WC Water Column for Propane Use the 1 8 pipe tap on the burner manifold for checking pressure Make sure the gas piping is clean and free of obstructions dirt and piping compound An adequate gas supply is necessary Un...

Page 6: ...xibility With one burner off and the second burner set low up to both burners full on you can move from low simmer on up to 110 000 BTU hr input Fig 1 Fig 2 LIGHTING INSTRUCTIONS 1 Turn all burner valves to OFF position and wait 5 minutes 2 Turn gas shutoff valve ON 3 Light standing pilot with a lit taper Adjust pilot to high flame if necessary by turning pilot valve adjusting screw see Fig 1 coun...

Page 7: ... STOCKPOT RANGE AND ITS PARTS ARE HOT USE CARE WHEN OPERATING CLEANING OR SERVICING SERVICE Contact your local Service Agency for any repairs or adjustments needed on this equipment TROUBLESHOOTING PROBLEM POSSIBLE CAUSES Pilot Outage 1 Pilot flame too low 2 Restriction in pilot orifice 3 Restriction in pilot valve Improper burner combustion Improper ventilation Poor Ignition 1 Insufficient gas in...

Reviews: