CLEANING 
 

Top grate(s) may be immersed in strong commercial cleaning compound overnight.  In the 
morning, rinse with hot water to remove any residues of cleaning compound.   
 
Stainless steel surfaces may be cleaned using damp cloth with mild detergent and water 
solution. 
 
Places where fat, grease, or food can accumulate must be cleaned regularly. 
 
 

MAINTENANCE 

 

WARNING

: THE STOCKPOT RANGE AND ITS PARTS ARE HOT.  USE CARE WHEN 

OPERATING, CLEANING, OR SERVICING.   
 

SERVICE 

 
Contact your local Service Agency for any repairs or adjustments needed on this 
equipment. 
 

TROUBLESHOOTING 

 

PROBLEM POSSIBLE 

 

CAUSES 

Pilot Outage 

  1.  Pilot flame too low 
  2.  Restriction in pilot orifice 
  3.  Restriction in pilot valve 

Improper burner 
combustion 

   Improper ventilation 

Poor Ignition 

 1. Insufficient 

gas 

input 

  2.  Poor air-gas adjustment 
  3.  Restriction in pilot orifice 
  4.  Restriction in main burner ignition port 
  5.  Restriction in control valve 
  6.  Restriction in gas orifice 

  

 

Summary of Contents for ML-052822

Page 1: ...TAIN THIS MANUAL FOR FUTURE USE FORM F 36951 04 07 INSTALLATION OPERATION MANUAL FOR Stockpot Range MODELS MLS VSP100 ML 052822 VSP200 ML 052823 VSP200F ML 769292 www vulcanhart com MODELS MLS WSPR1 ML 760600 WSPR2 ML 760601 WSPR2F ML 769292 www wolfrange com VSP100 WSPR2F ...

Page 2: ...PORTANT IN THE EVENT A GAS ODOR IS DETECTED SHUT DOWN UNITS AT MAIN SHUTOFF VALVE AND CONTACT THE LOCAL GAS COMPANY OR GAS SUPPLIER FOR SERVICE FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE WARNING IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE INJURY OR DEATH READ THE I...

Page 3: ...the clearance dimensions see below agree with the specifications on the rating plate which is located at the back of the stockpot LOCATION The installation location must be kept free and clear of combustibles Do not obstruct the flow of combustion and ventilation air DO NOT install the stockpot adjacent to open burners or fryers Sufficient air should be allowed to enter the room to compensate for ...

Page 4: ...tion Association Batterymarch Park Quincy MA 02269 In Canada 1 Local codes 2 CAN CSA B149 1 Natural Gas Installation latest edition 3 CAN CSA B149 2 Propane Installation Code latest edition available from the Canadian Gas Association 178 Rexdale Blvd Etobicoke Ontario Canada M9W 1R3 GAS PRESSURE REGULATOR INSTALLATION Gas regulator pressure is preset at 5 Water Column W C for natural gas and 10 W ...

Page 5: ... A pressure regulator is supplied and must be installed outside of the broiler when making the gas supply connection Standard orifices are set for 5 WC Water Column for Natural Gas 10 WC Water Column for Propane Use the 1 8 pipe tap on the burner manifold for checking pressure Make sure the gas piping is clean and free of obstructions dirt and piping compound An adequate gas supply is necessary Un...

Page 6: ...xibility With one burner off and the second burner set low up to both burners full on you can move from low simmer on up to 110 000 BTU hr input Fig 1 Fig 2 LIGHTING INSTRUCTIONS 1 Turn all burner valves to OFF position and wait 5 minutes 2 Turn gas shutoff valve ON 3 Light standing pilot with a lit taper Adjust pilot to high flame if necessary by turning pilot valve adjusting screw see Fig 1 coun...

Page 7: ... STOCKPOT RANGE AND ITS PARTS ARE HOT USE CARE WHEN OPERATING CLEANING OR SERVICING SERVICE Contact your local Service Agency for any repairs or adjustments needed on this equipment TROUBLESHOOTING PROBLEM POSSIBLE CAUSES Pilot Outage 1 Pilot flame too low 2 Restriction in pilot orifice 3 Restriction in pilot valve Improper burner combustion Improper ventilation Poor Ignition 1 Insufficient gas in...

Reviews: