Troubleshooting
OptiFlex 2 B
Fault
Causes
Troubleshooting
although the gun is
triggered and sprays
powder
insufficiently grounded
quality
High voltage and current
deactivated
Press the selection key
(application key)
High voltage cascade
defective
Contact local Gema
representative
The powder is not
fluidized
Compressed air not
present
Connect the equipment
to the compressed air
Fluidizing air is set too
low on the control unit
Set the fluidizing air
correctly
Throttle motor defective
Contact local Gema
representative
No electrode rinsing air
Rinsing air throttle motor
defective
Contact local Gema
representative
Vibrator not functioning
Vibrator/condenser
broken
Contact local Gema
representative
Vibrator not plugged in
plug in
Incorrect equipment
type configured
Configure parameter P0
(See operating
instructions for the
OptiFlex 2 CG09
manual gun control unit,
Chapter "Initial Start-up
– Setting Equipment
Type")