General safety regulations
OptiFlex 2 B
Powder lying on the floor around the powder spraying equipment is a
potentially dangerous source of slipping. Booths may be entered only in
the places designed for this purpose.
Static charges
Static charges can have the following consequences: Charges to people,
electric shocks, sparking. Proper grounding must be in place to prevent
objects from becoming charged.
Grounding
All electrically conductive parts found within 5 meters around each booth
opening, and in particularly the objects to be coated, must be grounded.
The grounding resistance of each object must amount to maximally
1 MOhm. This resistance must be checked/tested regularly when starting
work.
The condition of the work piece attachments, as well as the hangers,
must guarantee that the work pieces remain grounded. The appropriate
measuring devices must be kept ready in the workplace, in order to
check the grounding.
The floor of the coating area must conduct electricity (normal concrete is
generally conductive).
The supplied grounding cable (green/yellow) must be connected to the
grounding screw of the electrostatic manual powder coating equipment.
The grounding cable must have a good metallic connection with the
coating booth, the recovery unit and the conveyor chain, respectively with
the suspension arrangement of the objects.
Smoking and open flames are forbidden in the entire plant area! No work
that could potentially produce sparks is allowed!
Slipping
danger
No smoking or open
flames
Strict compliance
with grounding
requirements