24
Initial start-up
OptiFlex 2 C
Description
Presetting
Powder output
50%
Total air
4.0 Nm³/h
High voltage
80 kV
Spray current
80 µA
Electrode rinsing air
0.1 Nm³/h
Fluidizing air
0.0 Nm³/h (for OptiFlex-C)
8. Setting the total air volume
correct powder cloud
too little total air
Note:
A total air volume of 4 Nm³/h and a 50% powder share are
recommended as the base values.
9. Adjust the powder output volume (e.g. according to the desired
coating thickness)
or
much powder
little powder