V
05/10
OptiFlex B manual coating equipment
Color change
21
Color change
General information
When a color change takes place, the individual components of the ma-
nual coating equipment must be cleaned carefully. Thereby, all powder
particles of the former color must be removed!
Procedure:
1. Clean the fluidizing/suction unit
2. Clean the powder hose:
-
Strip the powder hose from the hose connection on the
injector
-
Point the gun into the booth
-
Blow through the hose manually with a compressed air
gun
-
Fit the powder hose again to the hose connection on the
injector
3. Dismantle and clean the powder gun (see therefore the user ma-
nual of the OptiSelect manual powder gun)
4. Clean the injector (see therefore the user manual of the OptiFlow
injector)
5. Prepare the manual coating equipment with new powder for
start-up