ORBIMAT CA
| Operating instructions
Set-up and assembly
(09.03.15) OW_ORBIMAT_CA_BA_871060202_04_EN
orbitalum tools
GmbH, D-78224 Singen, www.orbitalum.com, Tel. +49 (0) 77 31 792-0
21
5
6
4
3
7
2
1
1. Gas quantity setting
2. Connection of BUP Control Box
3. Connection oxygen meter ORB
4. Key switch
5. Connection Remote control/dummy
plug
6. STOP indicator (with EMERGENCY
STOP active)
7. Multicard reader
Fig. 3:
Front panel: Connections and control elements
Remote control connection
Connection for remote control (optional) or dummy plug.
If remote control is not being used and the dummy plug is not inserted, most of the system is deenergized. The pilot
light in the red main switch lights up, and the STOP indicator for active EMERGENCY-STOP lights up red.
Key switch
The key switch disables procedure modification.
A shortened selection menu (main menu) appears if procedure modification is disabled.
Key position (as shown): Modification enabled In the "disabled" key position, the key can be removed.
Connection oxygen meter
Connection of a residual oxygen meter (optional).
For continuous monitoring of the forming gas: The portion of residual oxygen remains below a percental portion which can
be set at the device (e.g. 70 ppm).
Connection of BUP Control Box
For supplementary devices for control of the forming gas pressure (BUP: BackUp Pressure Control) (optional). These
supplementary devices record the gas pressure inside the pipe using a pressure sensor and change it using a control-
lable gas valve.
Multicard reader
For the exchange of procedures between multiple machines, for the creation of backup copies of the system data and
for updating the system, languages, header data and the database for auto programming.
Memory cards which can be used: CF, SD, MMC, Smart Media and Sony Memory Stick.
Gas quantity setting (weld gas)
Adjusting screw with sight glass for setting the weld gas quantity.
Other connection options (on device rear)
Optionally, the connection of an external keyboard (included in the scope of delivery) or an external printer and/or
monitor to the rear of the device is possible.