9. SERVICE AND TROUBLESHOOTING
9.1
Performing service work
X
In the main menu, select "
System settings
" > "
Service
".
The following display appears:
Fig. 33:
Service menu
9.1.1
Pumping out coolant
Use when changing the coolant and emptying the tank in case of longer machine standstill.
1. Connect drain hose on the flow connection (blue).
2. Lead drain hose into a suitable container to catch the coolant (approx. 2.5 liters).
3. Press "
Pump out water
" button".
A message appears. The coolant is pumped out of the flow connection of the machine (blue) without the water sensor in
the return being able to interrupt the process. To protect the pump against dry running, this process is limited in time to
approx. 30 seconds.
4. Select "
Abort
" when the coolant is fully pumped out to avoid unnecessary dry running of the pump.
If the tank is not pumped empty:
X
Start process again.
Additional information can be found in "Commissioning power source" (see chap. 7.4.2, p. 26).
9.1.2
Performing motor calibration
Use in checking and correcting the motor speed.
If several weld heads of the same type are used, a motor calibration should always be carried out before use.
If using different weld head models, this is not required, as the machine saves a separate deviation for each head model.
Continuously large and constantly different speed deviations are an indicator of a defect in the power source or weld
head if this cannot be compensator for via motor calibration.