ORBITALUM TOOLS GmbH
D-78224 Singen www.orbitalum.com
[REV. 20200320] OC_PS_BA_790048761_00__INH-02_EN
58
Operation
PS 4.5 PLUS
eNGLISH
WARNING!
Flying, hot and sharp-edged chips, tube surfaces, cutting edges and tools!
Danger of injury to eyes and hands.
X
Do
not
reach into the rotating tool during working.
X
Never
work without the saw chip guard mounted.
X
Wear recommended protective clothing, as described in chap. 2.4, p. 38.
X
Before transportation or changing the workplace, switch off the machine, wait until the
machine/tool stops running and pull the mains plug. Remove chips with tightfitting
safety gloves (in accordance with DIN EN 388 and EN 407) using suitable tools (e.g.
tongs or screwdriver).
X
Make sure the chips guard is working.
ATTeNTION!
Restarting the machine following blockage!
Diverse physical injuries and material damage.
X
In the event of a blockage, always disconnect the machine from the power supply before
clearing it.
X
If necessary, remove any tensioned parts before restarting the machine.
ATTeNTION!
Vapors when working with lubricants!
Damage to lungs, skin and the environment.
X
Only use original lubricant recommended by Orbitalum Tools.
9.1
cutting the tube (saw position 1)
9.1.1
Shutting down (even in an emergency)
WARNING!
EMERGENCY STOP function not available by unplugging the power plug!
Diverse physical injuries and material damage.
X
Do
not
use angled power plugs.
X
Do
not
use click-in socket outlets and click-in power plugs (blue CEE power plugs) for
power connection, otherwise the EMERGENCY STOP does not function. The user must
check whether the power plug can be pulled out of the outlet by the cable.
X
Only use original Orbitalum Tools parts.
X
Ensure free access to the power plug.
X
Leave the danger zone until the machine stops moving.
To be able to stop the machine (also in case of emergency), perform the corresponding steps and immediately remove from the
danger area, until the machine comes to a stop:
2
1
If the fixing button (2) is not locked:
X
Release ON/OFF switch (1).
If the fixing button (2) is locked:
X
Actuate and release ON/OFF switch (1).
If the ON/OFF switch (1) no longer functions:
X
Remove the plug from the socket or vacate the danger zone
as quickly as possible and then unplug the power plug.