CMTinyCMTinyIQ_UM_9752097710_NL_D_GB_F_V1_1
63
GB
9 Faults
Warning:
-
Disconnect the power supply before carrying out work on the unit.
-
Work must only be carried out on the equipment by an electrical engineer with the
relevant training and qualifications.
Table 2, Fault overview chart CM Tiny (connection diagram, analogue 5.3.1)
Problem
Possible cause
Solution
All LEDs are off
No supply voltage
Switch on 24 V DC supply
voltage
Wiring fault
Locate fault and remedy, see 5.3
Cable break in the M12
connection cable/connector
Replace M12 cable/connector
LEDs do not light
up orange, keep
flashing green
High voltage set too low
Increase output voltage by
increasing setpoint (5.3/6.2)
No signal on the
Remote On/Off input
Connect 24 V DC (±3 V) to the
"Remote On/Off" input
LEDs light up red
Output voltage set too high,
arcing at the charging
bar/electrode
Reduce output voltage by
reducing setpoint or increasing
distance to earth
Short circuit between charging
bar/electrode or HV cable and
earth
Locate short circuit and eliminate
LEDs are flashing
red, slow, 1 Hz
Supply voltage too low
Restore 21–27 V DC supply
voltage on M12 connector
"HV OK" output overloaded
Eliminate overload (24 V DC >
50 mA)
Generator overheated
Make sure the ambient
temperature is lower than 55 ºC
Summary of Contents for Simco-ION Charge Master Tiny
Page 22: ...CMTinyCMTinyIQ_UM_9752097710_NL_D_GB_F_V1_1 21 NL Reserveonderdelen ...
Page 45: ...CMTinyCMTinyIQ_UM_9752097710_NL_D_GB_F_V1_1 44 Ersatzteile ...
Page 67: ...CMTinyCMTinyIQ_UM_9752097710_NL_D_GB_F_V1_1 66 Spare parts ...
Page 89: ...CMTinyCMTinyIQ_UM_9752097710_NL_D_GB_F_V1_1 88 Pièces de rechange ...