32
5.2.3. Power unit for EP-Sh-N bar
Read the power unit manual.
Fit the power unit in your chosen position.
Connect the power unit to the (mains) voltage.
5.3. Connecting the anti-static bar
5.3.1. EP-Sh-N anti-static bar
7. Fit the HV cable to the power unit, using the assembly clamps supplied.
8. Fit the gland of the screen in the power unit.
9. Connect the HV cable to the terminal block in the power unit.
Warning:
Do not kink the high voltage cables and do not lay them in sharp curves.
Please refer to the power unit manual.
5.3.2. P-Sh-N-Ex anti-static bar
Lay the connection cable to the (mains) voltage connection.
Fit a fuse (200 mAT at 230 V or 400 mAT at 115 V) in the connecting line.
A neon lamp (230 V) can be fitted as high-voltage indicator between the black wire and
earth.
Hook up the connecting cable.
Warning:
Make sure the supply voltage is correct (see rating plate).
See P-Sh-N-Ex manual
5.4. Blower (option)
Read the blower manual.