CleanIONVAC11_UM_9752073020_NL_D_GB_F _V1_0
31
GB
5. Technical specifications
5.1. Dust collector type
VAC11
Frequency
50 Hz
60 Hz
Part number
3703102450
3703102460
Power
1.3 kW
1.5 kW
Mains voltage
400 V AC - 3 ph.
400 V AC - 3 ph.
Electrical safety
Grade 1
Air displacement
140 m³/h
170 m³/h
Vacuum
-170 mbar
-210 mbar
Hose connection
50 mm diameter
50 mm diameter
Filter
Filter bag, polyester needle filter 500 g/m²
Optional filter
Vlisco disposable bag
Operating conditions
industrial
Ambient temperature
0 – 50
C, max. 90% RH, non-condensing
5.2. Power unit
Secondary voltage
7 kV AC
Secondary current
max. 2.5 mA
Maximum load
see Section 5.3: Maximum power unit load
High-voltage output
2x, designed for use with Simco-Ion A3030 high-voltage
connector with shielded high-voltage cable
5.3. Maximum power unit load
The load on the integrated power unit is determined by the ionisation equipment connected and
the shielded connecting cable used. The capacitive load of the equipment and cables must be
added together in order to calculate the total load of the power unit.
Note:
- The maximum output current of the power unit is 2.5 mA.
- The maximum capacitive load of the power unit is 1500 pF.
Ionisation equipment
Load per metre
Type MEB anti-static bar
75 pF*
Type EP-Sh-N anti-static bar
50 pF*
Type P-Sh-N anti-static bar
100 pF*
Connection cable
Shielded cable, 7 kV equipment
125 pF
Shielded cable, junction block
125 pF
*
In the case of daisy chained anti-static bars, add the length of both anti-static bars.
See Table 1 for details of the total load and load capacity of the power unit.
Example — a cleaning system with:
♦
One
MEB
anti
‐
static
bar
with
a
total
effective length of 2 metres connected to a 3-meter shielded high-voltage
cable: 2 x 75 pF + 3 x 125 pF
♦
The
power
unit's
total
load
will
then
be:
1