6.4. Neutralizing
To measure the efficiency of the anti-static bar, a field-strength meter can be used.
Connect the field-strength meter to earth, and maintain a minimum distance of 30 cm to the
anti-static bar.
Measure the static charge on the material before and after it has passed the Thunder
ION
.
The charge measured should be minimized after the product has passed the anti-static bar.
7. Maintenance
Warning:
When working on the equipment, always disconnect the power supply to
the equipment.
Attention:
Do not damage the emitters.
The emitters must not be removed when (wet) cleaning the bar.
Keep the anti-static bar clean.
If fouled: clean the anti-static bar with a hard non-metal brush.
If fouled: clean the anti-static bar with a block brush and isopropyl alcohol.
Blow the anti-static bar completely dry before use.
Veconova 10 may also be used in the event of stubborn fouling (www.eco-nova.nl)
During cleaning, clean the mounting surface of the emitters as well as the rest of the housing
(including the groove alongside the mounting surface of the emitters and the external
surfaces).
Damaged or worn emitters can be replaced, item numbers:
-7510990000 (emitter with screw connection)
-7510990020 (emitter with click connection)
Only replace emitters on a clean, dry anti-static bar.
Maximum rotating torque (screw connection) = 1 Nm = 0.1020 kgf.m = 141.6 ozf.in