9
9A
EQUICALOR -
AS 1000
INSTRUCTIONS SHEET AS1000
300538US-10-14
TECHNICAL CHARACTERISTICS
TRANSMISSION
• frequency: 915.00 MHz
• Signal range: 33yd with no ob-
stacles
POWER SUPPLY
• Voltage: 4.5 V
• Type of batteries: 3 AA stylus alka-
line batteries (mod. LR6) 1.5V
• Battery life: 3 years (with brand
new, well stored batteries and in op-
timal operating conditions)*
• Type of device: Digital electronic
CONNECTION
• Type of connection: M30x1.5
• Closing distance
X
: between
0.41 and 0.47 in; see figure
17
ENVIRONMENTAL CONDITIONS
• Temperature limits for
transport and storage:
from -4°F to +130°F
• Operating temperature
limits: from 23°F to +110°F
OVERALL DIMENSIONS
(in) L=3.60, H=1.90, W=2.60
PRODUCT CODE
• Description: axial
servomotor
• EQUICALOR-A: Art. AS
1000 - Code 506364US
BATTERY STORAGE
CONDITIONS
• Temperature: 68 °F
ensure long battery life
SAFETY
• Insulation: CLASS III
CONTACTS
IVAR US, Inc.
Mailing Address:
PO Box 8015, Elkridge, MD 21075
T: 1-855-9-IVAR-US
www.ivar-us.com
info@ivar-us.com
I.V.A.R. S.p.A.
Via IV Novembre, 181
25080 Prevalle (BS) - Italy
T: +39 030 68028 - F: +39 030 6801329
www.ivar-group.com
info@ivar-group.com
CONDITIONS OF WARRANTY
I.V.A.R. S.p.A. is insured against damage caused to third parties due to product manufacturing defects
in accordance with the terms and limits set out in Legislative Decree 206/2005. The maximum insur-
ance coverage is € 3,000,000.00 per claim, per year. The liability of IVAR for damages caused by defec-
tive products is governed by the general sales conditions and by Legislative Decree 206/05 (art.114-
127) and is valid for 2 years after the product’s installation. I.V.A.R. S.p.A. ensures the compliance and
the proper functioning of its products in accordance with the terms of Legislative Decree 206/05.
ENGLISH
CONTENTS OF THE PACKAGE
• Actuator
• Utility key
*A
• Stylus alkaline batteries
• This Instructions sheet
BATTERY REPLACEMENT
The actuator requires 3 AA 1.5 V Alka-
line batteries. The batteries must be
inserted in order to operate the equipment.
1
To replace the batteries, use the utility
key, supplied in the package.
2
Release the battery slide, inserting the
utility key as indicated in Figure
2
.
3
Remove the battery housing slide and
arrange the batteries in the order and direc-
tion indicated on the bottom of the slide; see
Figure
3
and
3A
.
4
Reposition the slide, sliding it all the
way until it clicks.
NOTE: SEE THE MANUAL
ATTACHED TO THE CHRONOTHERMOSTAT TO
COMPLETE INSTALLATION.
INSTALLATING THE ACTUATOR
5
Make sure to have installed the batteries.
6
Remove (with a small screwdriver) the
fixing pin from upper numbered disc as in-
dicated in the figure.
7
Press the utility key into the housing.
8
Fully open the actuator, slowly turning
the key anti-clockwise until about 45° from
the limit switch
8A
, in order to align the pi-
ston
8C
with the minimum point. This point
is indicated in the figure in detail
8D
. Then
remove the key.
9
Raise the connecting threaded ring
nut
9A
in the direction indicated.
10
Secure the actuator to the radiator ma-
nually screwing down the threaded ring nut,
tightening it with an appropriate size wrench.
11
Fully close the actuator, maintaining the
front selector in position ’-’ until Led 4 flashes
for the first time (See Figure above - ACTUA-
TOR CONTROLS), which occurs after 5 seconds.
Release the button after this signal. The si-
multaneous rapid flashing of Leds 4, 5, and 6
indicates closure has occurred.
12
Remove the numbered disc located on the
upper part of the actuator (See figure).
13
Put the numbered disc back in place,
making sure the ‘0’ is aligned with the re-
ference mark (*); then press the disc in the
housing.
14
Put the fixing pin back in place.
15
To complete the assisted closure/ope-
ning phase, the selector
must
be kept in the
SELECT
position until Leds 3 and 4 light up,
which happens after 5 seconds. Release the
button after this signal.
16
Proceed with associating the actuator
and with the final test
(SEE THE MANUAL AT-
TACHED TO THE CHRONOTHERMOSTAT).
LED 1
LED 2
LED 3
LED 4
LED 5
LED 6
FRONT
SELECTOR
Position
‘SELECT’
PRESS
ACTUATOR
CONTROLS
Position ‘+’
PUSH
UPWARDS
Position ‘-’
PUSH
DOWN-
WARDS
( X )
MAX= 0.37 in
MAX= Ø0.83 in
M30x1,5
10
12
8A
7
6
8D
OPEN
THIS WAY
3
MIN
MAX
8C
3A
17
2
*
13
14
*A
FCC ID: 2AB4Y506364US
This device complies with part 15 of the FCC
Rules. Operation is subject to the following
two conditions: (1) this device may not cause
harmful interference, and (2) this device must
accept any interference received including in-
terference that may cause undesired operation.
NOTE:
this equipment has been tested and
found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC
Rules. These limits are designed to provide rea-
sonable protection against harmful interference
in a residential installation. This equipment ge-
nerates, uses, and can radiate radio frequency
energy and, if not installed and used in accor-
dance with the instructions, may cause harmful
interference to radio communications. However,
there is no guarantee that interference will not
occur in a particular installation. If this equip-
ment does cause harmful interference to radio
or television reception, which can be determined
by turning the equipment off and on, the user is
encouraged to try to correct the interference by
one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equip-
ment and receiver.
• Connect the equipment into an outlet on a cir-
cuit different from that to which the receiver is
connected.
• Consult the dealer or an experienced radio/TV
technician for help.
RF Exposure:
this equipment complies with FCC
radiation exposure limits set forth for an uncon-
trolled environment. This equipment should be
installed and operated with min. distance 20 cm
between the radiator and your body. This trans-
mitter must not be co-located or operating in
conjunction with any other antenna or transmitter.
Warning:
Changes or modifications to this devi-
ce not expressly approved by IVAR Spa could void
the user’s authority to operate the equipment.
* battery life may be shortened by bad RADIO transmission conditions (L SIGN), by the presence of
obstacles or by storage conditions other than those prescribed. Batteries of different brands may
have different behaviour and lower life than indicated in the present document.