background image

!

                     

*

Note:

    

                                                                                                                                                                     

Valid operator ID# card is required during system installation to enable vehicle operation 
(Verification of electrical connection of the BLUE and GREEN wires connected in series to one 
of the vehicle seat switch wire) and to be able to access the “Administration Menu”.    

    

                                                                                                                 

 

                                                                                                                         

Selecting the mounting location for digital indicator 

Use the mounting bracket with the anti vibration mount and fasten digital indicator on the vehicle dashboard, side railing 
on  the  right  hand  side  or  preferably  on  the  overhead  guard.  There  are  many  examples  of  mounting  locations  that  will 
depend on the vehicle model. However, additional mounting items such as a flat brackets may be needed to help secure 
the unit  to upper right corner of the guard or side railing.  

  Choose the correct location and make sure that:                                                                                                               
- Indicator is visible and within reach of the operator                                                                                                          
- Location so that operator has a clear unobstructed view of the working environment 

Electrical connections 

 All SkidWeigh Plus RFID equipped systems operate from 12 to 55 VDC. 

                                                                                                                           

  

 

                                     

Orange Wire 

(+) Ignition switch                                                                                                                    

Brown Wire

 (-) Battery negative 

                                                                                                                                                                                 

Internal relay connections to be used to enable vehicle usage 

(Dry contacts) 

BLUE  Wire,

 common                                                                                                                      

GREEN Wire

, N. O. contact   

 

 

                                    

                                                                                                                      

                                                                                                      

      

                                                                                                                                             

 

                                                                                                                                                        

 

Integrated Visual Data Technology Inc.   3439 Whilabout Terrace, Oakville, Ontario, Canada  L6L 0A7 

www.skidweigh.com

   

Power Supply 12 to 55 VDC 
Ignition  ORANGE WIRE 
Battery Negative (-) BROWN WIRE

Vehicle seat switch interface 

Use two wires 

BLUE 

and

 

GREEN 

and connect 

them is series with vehicle seat switch wire 

Normally Open Contacts

               

        Power Supply

 

(+)

 

ORANGE Wire

Connect to ignition switch 

(-)

 

BROWN Wire,

 

Connect to battery negative

Summary of Contents for IM4-RFID

Page 1: ...Safety Check RF Wireless IM4 RFID M Integrated Visual Data Technology Inc 3439 Whilabout Terrace Oakville Ontario Canada L6L 0A7 www skidweigh com IMPORTANT NOTE Please read first the ProxPoint Plus card reader information on the end of this manual referring to the programming method that is required to get the system up and running RFID Proximity Card Reader ...

Page 2: ...ceptable methods of making a wire connections Soldering your connections recommended Crimp connectors with the use of the proper crimping tool Regardless of the method you choose ensure that the connection is mechanically sound and properly insulated Use high quality electrical tape and shrink tubing where necessary This product is connected directly to the vehicle s ignition switch 12 to 55 VDC T...

Page 3: ...orner of the guard or side railing Choose the correct location and make sure that Indicator is visible and within reach of the operator Location so that operator has a clear unobstructed view of the working environment Electrical connections All SkidWeigh Plus RFID equipped systems operate from 12 to 55 VDC Orange Wire Ignition switch Brown Wire Battery negative Internal relay connections to be us...

Page 4: ... the administration menu to set up and calibrate the system IM4 RFID and SkidWeigh Plus series Integrated Visual Data Technology Inc 3439 Whilabout Terrace Oakville Ontario Canada L6L 0A7 www skidweigh com RFID Reader Keypad Enter key Toggle Arrows Keys in set up menu Select function in F 0 and F 9 menu Optional Functions Print Key or and SEND key to wireless base station FUNCTION MODE KEY F9 F0 ...

Page 5: ...the applications without Base Station select MANUAL _ set clock and follow the LCD instructions LCD Display MENU PASSWORD _ LCD Display KEY to SCROLL F KEY TO EXIT LCD Display SET CLOCK ENTER TO SELECT LCD Display SET CLOCK AUTO _ LCD Display SET CLOCK MANUAL _ Integrated Visual Data Technology Inc 3439 Whilabout Terrace Oakville Ontario Canada L6L 0A7 www skidweigh com How to disable RFID reader ...

Page 6: ...e ID Maximum input number for vehicle ID is 4 digits Note For system used with RFID card reader maximum input number for vehicle ID is 5 digits LCD Display Aug 28 2010 12 20 23 LCD Display KEY to SCROLL F KEY TO EXIT LCD Display SET VEHICLE ID ENTER TO SELECT LCD Display ENTER VEHICLE ID 1_ LCD Display VEHICLE ID CONFIGURATED Integrated Visual Data Technology Inc 3439 Whilabout Terrace Oakville On...

Page 7: ...will prompt you to erase the SDRAM all files contained on the SKidWeigh Plus ED3 IM Once you have made your selection Y or N the system will automatically bring you back to the main screen in the supervisor menu LCD Display KEY to SCROLL F KEY TO EXIT LCD Display SAVE TO USB ENTER TO SELECT LCD Display SAVING TO USB LCD Display ERASE SDRAM N LCD Display KEY to SCROLL F KEY TO EXIT Integrated Visua...

Page 8: ... Use left or right arrow for desired low impact value Press Enter key Use left or right arrow for desired low impact value Press Enter key to select Use left or right arrow for desired high impact value Press Enter key to select LCD Display SET IMPACT ENTER TO SELECT LCD Display ENTER LOW IMPACT 4 0 G LCD Display ENTER HIGH IMPACT 8 0 G Integrated Visual Data Technology Inc 3439 Whilabout Terrace ...

Page 9: ...To change F Fail to P Pass press left or right arrow key The LCD will change to P and press Enter key to confirm selection System will automatically advance to next OSHA safety check message Follow above procedure for all next OSHA safety check messages by inputing the F or P After the last safety check message input F or P is done the LCD display will go back and show date time and vehicle operat...

Page 10: ...ly only one valid operator RFID card Programming RFID operator cards Turn ignition switch to on position The LCD display will indicate to SCAN CARD Scan RFID MASTER CARD LCD display will show Scan first valid HID operator card The LCD display will show for the moment the value of the inputed card The LCD display will indicate that CARD ADDED OK and short beep once LCD Display SCAN CARDS KEY TO EXI...

Page 11: ...n RFID MASTER CARD LCD display will show Scan first valid operator CARD that you want to delete from the system LCD display will show the card ID Use left and right arrow key to change to Y The current card ID 44444 will be deleted from the system LCD display will automatically show Scan next valid operator CARD that you want to delete from the system Follow instructions shown on LCD display Keep ...

Page 12: ...er will be disabled Vehicle will be operational without RFID operator card input How to enable RFID reader With LCD display showing Date Tome press F key and than press number 9 LCD display will show PASSWORD _ Input 521 KEY TO SCROLL and follow instructions Use left or right arrow key to toggle to Y and press Enter key LCD Display RE ACTIVATE RFID ENTER TO SELECT LCD Display RE ACTIVATE RFID TURN...

Page 13: ...red green and red Transient Surge and Reverse Voltage Protection Extra Security Recognizes card formats up to 85 bits with over 137 billion unique codes Application for all kinds of lift trucks regardless of the vehicle make type model or operating voltage Self programming no additional devices required to add or delete cards from the system Memory capacity to up to 250 operators ID FCC Compliance...

Reviews: