Administration Menu
Instructions
To enter into the
Administration Menu
scan valid operator RFID card,
press
F key and than 9
key
and input password
521
.
Use left and right arrow keys to scroll and follow the LCD
instructions.
Date / Time Set Up
Use left
◀
and right
▶
arrow key
(
bottom left side of the keypad)
to change from AUTO to MANUAL date/time set up.
Note:
AUTO set up refers to system utilizing a wireless RF platform with automatic date /time update from IVDT Base
Station communication and programming hub.
For the applications without Base Station, select MANUAL _ set clock and follow the LCD instructions.
LCD Display
MENU
PASSWORD = _
LCD Display
<> KEY to SCROLL
F KEY TO EXIT
LCD Display
SET CLOCK
ENTER TO SELECT
LCD Display
SET CLOCK
AUTO _
LCD Display
SET CLOCK
MANUAL _
Integrated Visual Data Technology Inc. 3439 Whilabout Terrace, Oakville, Ontario, Canada L6L 0A7
How to disable RFID reader
Vehicle access enable function in case of lost RFID master card, valid
card(s) or reader malefaction
- With LCD Display showing “ IVDT SCAN CARD” press and hold
F
key for
5 seconds
- LCD display will show PASSWORD =_
- Input
521
and RFID reader will be disabled. Vehicle will be operational
without RFID operator card input.