installation directiVe
2
MAY 2006
N40 ENT M25
N60 ENT M37-M40
Throttle lever position sensor
After testing the working condition of the linkage, adjust the
run of the servo components (see Chapter 18).
o
With the throttle at idle setting, the potentiometer rod
has to be in the resting position.
o
With the throttle at the stop, the potentiometer rod has
to be in the position of maximum run out.
Water presence in the pre-filter sensor
1. Pre - filter - 2. Conductor to be connected
with the negative battery terminal.
CAUTION
in order to enable the proper working of the sensor to
detect water in the fuel, it is necessary that the pre-filter
support is connected electrically to the negative battery
terminal.
In the engine models which use parts with insulated poles
it is necessary to electrically insulate the pre-filter support
from the boat mass and then connect the support with the
negative battery terminal.
Figure 1b
05_018_V
2
1
Summary of Contents for NEF N40-ENT-M25
Page 64: ...INSTALLATIONDIRECTIVE 64 N40 ENT M25 N60 ENT M37 M40 MAY 2006 ...
Page 69: ......