4
QUICK START GUIDE
PtyP:
Program Settings (daily/weekly)
d_Pr (daily)
h_Pr (weekly)
tSEt:
Setting Time and Day
hSEt:
Weekly Program Setting
p_01
p_02
..........
p_12
ASEt:
Adaptive Start Parameters
P 01 (early turn-on time per degree)
P 02 (maximum early turn-on time)
oPEn:
Heat Loss Detection Parameters (Windows, doors, etc. left open)
P 01 (standby time)
P 02 (sensing temperature)
AnFr:
Anti-Frost Setting
off
on
uEr: S
oftware Version Monitoring
CodE:
Key Code
(introduction of Exclusive Keylocker)
CCod:
Erasing the Key Code
CntC:
Temperature Calibration
CLdr:
Display Brightness Adjustment
Resetting the settings (daily mode): Press and hold the upper two buttons ( )and ( )
simultaneously for ten seconds until you see “CLr” on the screen. Then the device goes to factory
settings.
Accessing settings: In order to access to the settings menu, use the On/Off switch ( ) on the side
to turn off the device. Press and hold the power button ( ) while switching on the unit from the
side. To turn off the device, please use the On/Off switch ( )on the side. To switch on, press and
hold the power button ( ). The device display shows the first option available in the menu. You
can switch between the options with the ( ) and ( ) buttons. To see and edit the details of an
option that appears on the screen, press and hold the power button ( ) for 3 seconds. To save
the changes, press and hold the power button ( ) for 3 seconds. To exit without saving, turn off
and back on the device via the on/off switch ( ) on the side.