Operating Instructions

AirX, AirModule E 9/15, Airbox E/S

6 720 809 065-00.1I

230V 1N~ / 400V 3N~

6 720 810 266 (2014/10)

Summary of Contents for Airbox E Series

Page 1: ...Operating Instructions AirX AirModule E 9 15 Airbox E S 6 720 809 065 00 1I 230V 1N 400V 3N 6 720 810 266 2014 10 ...

Page 2: ...le 13 7 Environment disposal 13 1 Key to symbols and safety instructions 1 1 Key to symbols Warnings The following keywords are defined and can be used in this document NOTICE indicates a situation that could result in damage to property or equipment CAUTION indicates a situation that could result in minor to medium injury WARNING indicates a situation that could result in severe injury or death D...

Page 3: ...s Do not use or store combustible or explosive materials paper propellants thinners paints etc withinthevicinityoftheappliance Do not use or store corrosive substances solvents adhesives chlorinated cleaning agents etc within the vicinity of the appliance 2 General Cooling is disabled in the UK model to comply with the regulations for RHI Heat pump AirX is together with heat pump module AirModule ...

Page 4: ...longside continued heat production however if the temperature is lower the defrosting is done by ways of a 4 way valve turning the heat medium direction in the circuit so that the hot gas from the compressor melts away the ice Function principle The heat production principle The fan sucks up air through the evaporator The energy in the air makes the refrigerant boil The resulting gas is drawn into...

Page 5: ...ris requiredifthe purpose of the heat pumpis also to produce hot water In this case switching between heating and DHW is managed by an external 3 way valve The integrated booster in the heat pump module will turn on if needed Fig 2 Heat pump AirX heat pump module Airbox with immersion heater external hot water cylinder Airbox S When heat pump AirX is connected to heat pump module AirBox S an exter...

Page 6: ...s this key to enter the information menu 6 Return key Press this key to return to the previous menu or to cancel changes For maintenance or when an error has been detected Press this key to switch between standard display and error message Keep this key pressed down to switch between a menu and the standard display 7 Selector Turn the selector to change a set value e g the temperature or to select...

Page 7: ...highlight Heating or Setback Press the selector Turn the selector to highlight desired setback operation setting Press the selector to activate selected setting When temperature control is activated turn the selector and press it to set the temperature The temperature setting value limits are determined by the settings for the other operating mode The user interface operates with the modified sett...

Page 8: ... the display is on press the selector Current selected heating circuit number operating mode and name optional is shown in the lower part of the display Turn the selector to select a heating circuit Only heating circuits that exist in the system are displayed for selection Wait a few seconds or press the selector The standard display displays the selected heating circuit Table 5 General Heating ci...

Page 9: ... is not plugged 5 7 Particle filter Check the heating system and collector system particle filters The filters will prevent dirt from entering the heat pump Operating problems might occur if these are blocked Cleaning the strainer Close the valve 1 Screw off the hood by hand 2 Take out the strainer and clean it by running water over it Put the strainer back it has rails that fit into the groove in...

Page 10: ... overheat protection on AirModule Pull out the front cover by the bottom and lift it off upwards Press the button hard on the overheating protection Put the front cover back To reset the overheat protection on AirBox E Contact the installer or retailer Fig 6 AirBox E 1 Pressure gauge Pressureswitchandoverheat protectionareonlyinheat pump module with integrated electrical supplement Overheat protec...

Page 11: ...Maintenance AirX AirModule E 9 15 Airbox E S 6 720 810 266 2014 10 11 Fig 7 AirModule 1 Reset overheating protection 2 Particle filter 3 Pressure gauge 1 6 720 810 156 10 1I 3 2 ...

Page 12: ...ld be cleared of dirt and leaves which inhibit defrosting Screw off the protective cover Clean the condensate pan with a cloth or soft brush Put the protective cover back Fig 8 Heat pump condensate pan 1 Condensate pan Warning The thin aluminum fins of the evaporator are sharp and delicate and can be damaged by negligence Wear gloves to protect hands from cuts Be careful not to damage the fins 6 7...

Page 13: ...ee the website for further information Login data for IP module Manufact no __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ Login name ___ ___ ___ ___ ___ ___ ___ ___ ___ Password __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ Mac ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ 7 Environment disposal Environmental protection is a fundamental corporate strategy of the Bosch Gr...

Page 14: ...boosterisaseparateheatsource whichisconnectedtothe heat pump module with pipework The heating from the booster is regulated via a mixing valve and is therefore also called a mixing valve booster The user interface manages the booster on off based on the currentheatingrequirements Theheatsourceiseitheranelectric oilor gas boiler Heat transfer circuit The part of the heating systemthat transfersheat...

Page 15: ...mperature inthisroomactsasthe control variable for the assigned heating circuit Switching time A certain time at which the heating system starts to heat or hot water is produced for example A switching time is a component of a time program Temperature of an operating mode Atemperaturethatisassignedtoanoperatingmode Thetemperatureis adjustable See the explanations on operating mode Flow temperature...