Settings Customer level
6 720 643 415 (2010/03)
18
Room temperature program when there are room
sensors:
>>
Room temperature program
>>>
Active program
If a program is selected, the following (if the menu
button is turned) is displayed:
>>>
View/edit active program
>>>
Room temperature normal
B
Set the desired set point for the room temperature.
>>>
Room temperature exception
B
Set the temperature that should apply as exceptional
temperature in the program.
The menu is displayed only if
Program 1
or
Program
2
has been selected.
>>>
Copy to all heating circuits
B
Select
Yes
to have the same control for all installed
circuits.
The menu is displayed only under
Circuit 1
.
Room temperature program when there is no room
sensor:
>>
Room temperature program
>>>
Active program
>>>
View/edit active program
The same as when there is a room sensor, see above.
>>>
Room temperature normal
B
Set the measured value in the room.
The indicated value is used by temperature programs
to calculate the difference between normal and
exceptional temperature.
>>>
Temperature increase/decrease
B
Use this function to adjust the room temperature so
that the normal room temperature (see the previous
menu) becomes the desired temperature.
B
Use this function to simply increase or decrease the
heat when there are no room sensors.
– – gives approx. 1 °C lower room temperature.
– gives approx. 0.5 °C lower room temperature.
+ gives approx. 0.5 °C higher room temperature.
++ gives approx. 1 °C higher room temperature.
>>>
Room temperature influence
Setting is carried out in the same way as in the menu
Room sensor
(
Æ
Chapter 10.2). The setting is used in the
temperature program to calculate how the flow line
temperature is affected when exceptional temperature
should apply.
>>>
Room temperature exception
The same as when there is a room sensor, see above.
>>>
Copy to all heating circuits
The same as when there is a room sensor, see above.
Factory setting
20.0 °C
Lowest value
10.0 °C
Highest value
35.0 °C
Tab. 16 Room temperature, normal
Factory setting
17.0 °C
Lowest value
10.0 °C
Highest value
30.0 °C
Tab. 17 Room temperature, exception
Factory setting
No
Alternative
No/Yes
Tab. 18 All circuits
Factory setting
20.0 °C
Lowest value
10.0 °C
Highest value
35.0 °C
Tab. 19 Room temperature, normal
Factory setting
=
Alternative
– – , – , =, +, ++
Tab. 20 Room temperature increase/decrease
It always takes some time for a change of a
heating setting, e.g. an increase or decrease
in room temperature, to apply. The same
applies in the event of a quick change of the
outdoor temperature. This is why you
should always wait for at least 24 hours
before making a new change.